Fraser-Johnston / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 8

355 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16355 / 355
EER2 · BTU/Wh11–12355 / 355
HSPF2 · BTU/Wh7.8–8.1355 / 355
Cooling capacity · BTU/h44,500–48,000355 / 355
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000355 / 355
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,200355 / 355
Heating capacity at 5°F / −15°C · BTU/h24,600–27,000355 / 355
COP at 5°F / −15°C2.1–2.42355 / 355
Equipment / loop typeHP - Split System355 / 355
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)355 / 355
Compressor stagingTwo-stage355 / 355
Connected capabilityNo355 / 355

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744489115.207.80262002.38EPA 4571164 →
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744488815.207.80264002.40EPA 4571167 →
CTU60C5XGS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21744488415.207.80256002.28EPA 4571170 →
CTF60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744488315.207.80256002.28EPA 4571171 →
CTM60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744487715.207.80256002.28EPA 4571172 →
CTU60C5XGS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21744487615.207.80258002.26EPA 4571173 →
CTF60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744487515.207.80258002.26EPA 4571174 →
CTM60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744487415.207.80258002.26EPA 4571175 →
CTM60C5CGS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21678629515.207.80260002.26EPA 4572126 →
CTF60C5CHS1+ furnace: Z8ES080C16LMPS1AHRI reference: 21678605615.207.80262002.36EPA 4572131 →
CTF60C5CHS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21678604115.207.80260002.38EPA 4572136 →
CTU60C5XGS1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21678585215.207.80258002.20EPA 4572141 →
CTF60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678583715.207.80258002.20EPA 4572146 →
CTM60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678582315.207.80258002.26EPA 4572151 →
CTU60C5XGS1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21678580815.207.80254002.24EPA 4572156 →
CTF60C5CGS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21678579315.207.80254002.24EPA 4572161 →
CTM60D5CGS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21678521915.207.80256002.28EPA 4572166 →
CTF60C5CHS1+ furnace: Z8ES120C20LMPS1AHRI reference: 21678500815.207.80262002.36EPA 4572171 →
CTM60C5CGS1+ furnace: Z8ES120C20LMPS1AHRI reference: 21678446515.207.80258002.26EPA 4572176 →
CTU60D5XGS1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 21678424715.207.80254002.24EPA 4572181 →