Fraser-Johnston / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 3

355 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16355 / 355
EER2 · BTU/Wh11–12355 / 355
HSPF2 · BTU/Wh7.8–8.1355 / 355
Cooling capacity · BTU/h44,500–48,000355 / 355
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000355 / 355
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,200355 / 355
Heating capacity at 5°F / −15°C · BTU/h24,600–27,000355 / 355
COP at 5°F / −15°C2.1–2.42355 / 355
Equipment / loop typeHP - Split System355 / 355
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)355 / 355
Compressor stagingTwo-stage355 / 355
Connected capabilityNo355 / 355

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CHS1+JMET16CS2N1AHRI reference: 21442662815.208.10264002.40EPA 3892776
CTM60D5CHS1+JMET18DS2N1AHRI reference: 21442663815.208.10262002.42EPA 3892787
JHC48C5CG2SS1AHRI reference: 21442669615.207.80248002.26EPA 3892792
CTM60C5CGS1+JME12C2SN1AHRI reference: 21442734015.207.80252002.30EPA 3892794
CTM60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21460529115.208.10264002.40EPA 3892818
CTM60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460536115.208.10264002.38EPA 3892822
CTM60C5CHS1+ furnace: Z9ES080C20SMPS1AHRI reference: 21460522115.207.80260002.36EPA 3892828
CTM60C5CHS1+ furnace: Z9ES100C16SMPS1AHRI reference: 21460522615.207.80266002.34EPA 3892834
CTM60D5CHS1+ furnace: Z9ES120D20SMPS1AHRI reference: 21460526115.207.80266002.36EPA 3892840
CTM60C5CHS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460528615.208.10266002.36EPA 3892843
CTM60D5CGS1+JMC20D2SN1AHRI reference: 21442861215.207.80254002.30EPA 3892854
CTM60C5CHS1+JME16C2SN1AHRI reference: 21442861715.208.10262002.42EPA 3892858
CTM60D5CHS1+JMC20D2SN1AHRI reference: 21442887515.208.10262002.42EPA 3892863
CTM60C5CGS1+JME16C2SN1AHRI reference: 21442900115.207.80254002.30EPA 3892866
CTM60C5CHS1+JMVT17CC2N1AHRI reference: 21442931615.208.10262002.40EPA 3892871
CTM60C5CHS1+JMC17C2SN1AHRI reference: 21442932115.208.10262002.40EPA 3892879
CTM60D5CGS1+JMVT20DC2N1AHRI reference: 21442936115.207.80254002.30EPA 3892885
CTM60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21460547615.208.10262002.40EPA 3892909
CTM60D5CGS1+JME18D2SN1AHRI reference: 21442744115.207.80254002.30EPA 3892919
CTM60D5CHS1+JMVT20DC2N1AHRI reference: 21442779715.208.10262002.42EPA 3892926

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.