XH548E2S11
LX SERIES · source records, page 2
355 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 355 / 355 |
| EER2 · BTU/Wh | 11–12 | 355 / 355 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 355 / 355 |
| Cooling capacity · BTU/h | 44,500–48,000 | 355 / 355 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 355 / 355 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,200 | 355 / 355 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,000 | 355 / 355 |
| COP at 5°F / −15°C | 2.1–2.42 | 355 / 355 |
| Equipment / loop type | HP - Split System | 355 / 355 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 355 / 355 |
| Compressor staging | Two-stage | 355 / 355 |
| Connected capability | No | 355 / 355 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
JHC48D5CG2SS1AHRI reference: 214428762 | 15.20 | 7.80 | 24800 | 2.26 | EPA 3559075 → |
CTF60C5CHS1+ furnace: TMLE080C20MP11AHRI reference: 214429016 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559090 → |
CTM60C5CHS1+ furnace: TM8Y100C20MP11AHRI reference: 214429149 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3559101 → |
JHC60C5CH2SS1AHRI reference: 214429311 | 15.20 | 8.10 | 26600 | 2.38 | EPA 3559105 → |
JSC48D5CG2SS1AHRI reference: 214833533 | 15.20 | 7.80 | 24800 | 2.26 | EPA 3560532 → |
JSE48D5CG2SS1AHRI reference: 214833538 | 15.20 | 7.80 | 24600 | 2.26 | EPA 3560537 → |
JHE48C5CG2SS1AHRI reference: 214424710 | 15.20 | 7.80 | 24800 | 2.10 | EPA 3627815 → |
CTF60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 215742977 | 15.20 | 7.80 | 26200 | 2.38 | EPA 3653169 → |
CTF60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 215742988 | 15.20 | 7.80 | 26000 | 2.40 | EPA 3653172 → |
CTF60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 215743113 | 15.20 | 7.80 | 26000 | 2.40 | EPA 3653191 → |
CTM60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 216437823 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815057 → |
CTM60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 216437828 | 15.20 | 7.80 | 26200 | 2.34 | EPA 3815062 → |
CTM60C5CHS1+ furnace: Z8ET080C16LMPS1AHRI reference: 216437833 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815067 → |
CTM60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 216437838 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3815072 → |
CTM60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 216437843 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815077 → |
CTM60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 216437848 | 15.20 | 8.00 | 25800 | 2.38 | EPA 3815082 → |
CTM60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 216437853 | 15.20 | 8.00 | 26400 | 2.36 | EPA 3815087 → |
CTM60D5CHS1+ furnace: Z9ET120D20SMPS1AHRI reference: 216437858 | 15.20 | 8.00 | 26600 | 2.36 | EPA 3815092 → |
CTM60C5CHS1+JMET12CS2N1AHRI reference: 214431902 | 15.20 | 7.80 | 25800 | 2.40 | EPA 3892765 → |
CTM60D5CHS1+JME18D2SN1AHRI reference: 214426072 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892774 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.