HH836E2S11
LX SERIES · source records, page 20
863 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 863 / 863 |
| EER2 · BTU/Wh | 10–12 | 863 / 863 |
| HSPF2 · BTU/Wh | 8–9.5 | 863 / 863 |
| Cooling capacity · BTU/h | 31,600–35,000 | 863 / 863 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,400 | 863 / 863 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 863 / 863 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 863 / 863 |
| COP at 5°F / −15°C | 2–2.1 | 863 / 863 |
| Equipment / loop type | HP - Split System | 863 / 863 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 863 / 863 |
| Compressor staging | Continuously variable | 863 / 863 |
| Connected capability | No | 863 / 863 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5AFS2+JME12C2SN2AHRI reference: 218637547 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4663966 → |
CTF36C5CDS2+JME12C2SN2AHRI reference: 218637541 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663972 → |
CTF36C5ADS2+JME12C2SN2AHRI reference: 218637535 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663978 → |
CTM48C5CFS2+JME16C2SN2AHRI reference: 218637528 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4663985 → |
CTM48C5AFS2+JME16C2SN2AHRI reference: 218637521 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4663992 → |
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 218637513 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4663997 → |
CTF36B5CDS2+JME12B2SN2AHRI reference: 218637506 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4664004 → |
CTF36B5ADS2+JME12B2SN2AHRI reference: 218637500 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4664009 → |
CTU48C5XFS2+JME12C2SN2+TXVAHRI reference: 218637493 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664014 → |
CTF48C5CFS2+JME12C2SN2AHRI reference: 218637487 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664020 → |
CTF48C5AFS2+JME12C2SN2AHRI reference: 218637481 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664026 → |
CTM36C5CDS2+JME12C2SN2AHRI reference: 218637475 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4664032 → |
CTM36C5ADS2+JME12C2SN2AHRI reference: 218637469 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4664038 → |
CTU48C5XFS2+JME16C2SN2+TXVAHRI reference: 218637463 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664044 → |
CTF48C5CFS2+JME16C2SN2AHRI reference: 218637457 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664049 → |
CTF48C5AFS2+JME16C2SN2AHRI reference: 218637451 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664054 → |
CTM36B5CDS1+JMC12B2SN1Cold climate designationAHRI reference: 214397681 | 18.00 | 9.00 | 24800 | 2.00 | EPA 3437712 → |
CTM36C5CDS1+ furnace: Z8ES080C16SMPS1Cold climate designationAHRI reference: 214584708 | 18.00 | 8.50 | 25400 | 2.00 | EPA 3438119 → |
CTM36C5CDS1+ furnace: Z8ES100C16SMPS1Cold climate designationAHRI reference: 214584713 | 18.00 | 8.50 | 26000 | 2.00 | EPA 3438124 → |
CTF36B5CDS1+ furnace: Z8ES100B12SMPS1Cold climate designationAHRI reference: 214584623 | 18.00 | 8.50 | 25000 | 2.00 | EPA 3438136 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.