HH836E2S11
LX SERIES · source records, page 19
863 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 863 / 863 |
| EER2 · BTU/Wh | 10–12 | 863 / 863 |
| HSPF2 · BTU/Wh | 8–9.5 | 863 / 863 |
| Cooling capacity · BTU/h | 31,600–35,000 | 863 / 863 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,400 | 863 / 863 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 863 / 863 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 863 / 863 |
| COP at 5°F / −15°C | 2–2.1 | 863 / 863 |
| Equipment / loop type | HP - Split System | 863 / 863 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 863 / 863 |
| Compressor staging | Continuously variable | 863 / 863 |
| Connected capability | No | 863 / 863 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5AFS2+ furnace: Z9ES080C16SMPS1AHRI reference: 218586307 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4650688 → |
CTM48C5AFS2+ furnace: TP9C100C16MP13AHRI reference: 218586282 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4650701 → |
CTM48C5AFS2+ furnace: TM9V100C16MP12AHRI reference: 218586267 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4650708 → |
CTM48C5AFS2+ furnace: Z8ES080C20LMPS1AHRI reference: 218586251 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650716 → |
CTM48C5AFS2+ furnace: Z8ES080C20SMPS1AHRI reference: 218586235 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650724 → |
CTM48C5AFS2+ furnace: Z8ES080C16LMPS1AHRI reference: 218586219 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650732 → |
CTM48C5AFS2+ furnace: Z8ES080C16SMPS1AHRI reference: 218586203 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650740 → |
CTM48C5AFS2+ furnace: TP9C080C16MP13AHRI reference: 218586179 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4650753 → |
CTM48C5AFS2+ furnace: TM9V080C16MP12AHRI reference: 218586164 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4650761 → |
CTM48C5AFS2+ furnace: Z8ES100C20LMPS1AHRI reference: 218586147 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650770 → |
CTM48C5AFS2+ furnace: Z8ES100C20SMPS1AHRI reference: 218586132 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650778 → |
CTM48C5AFS2+ furnace: TL8E100C20UH11AHRI reference: 218586118 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650784 → |
CTM48C5AFS2+ furnace: TL8E080C16UH11AHRI reference: 218586107 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4650788 → |
CTM48C5AFS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218586085 | 19.00 | 9.50 | 23400 | 2.00 | EPA 4650796 → |
CTM48C5AFS2+ furnace: Z9ET080C16SMPS1AHRI reference: 218586073 | 19.00 | 9.50 | 24200 | 2.00 | EPA 4650800 → |
CTF36C5CDS2+JME16C2SN2AHRI reference: 218637577 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663936 → |
CTF36C5ADS2+JME16C2SN2AHRI reference: 218637570 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663943 → |
CTM36C5CDS2+JME16C2SN2AHRI reference: 218637565 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663948 → |
CTM36C5ADS2+JME16C2SN2AHRI reference: 218637558 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663955 → |
CTM48C5CFS2+JME12C2SN2AHRI reference: 218637552 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4663961 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →