XH648E2S11
LX SERIES · source records, page 5
184 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 184 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 184 / 184 |
| EER2 · BTU/Wh | 11.7–12 | 184 / 184 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 184 / 184 |
| Cooling capacity · BTU/h | 45,500–48,000 | 184 / 184 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 184 / 184 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 184 / 184 |
| Heating capacity at 5°F / −15°C · BTU/h | 26,400–27,800 | 184 / 184 |
| COP at 5°F / −15°C | 2.1–2.38 | 184 / 184 |
| Equipment / loop type | HP - Split System | 184 / 184 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 184 / 184 |
| Compressor staging | Two-stage | 184 / 184 |
| Connected capability | No | 184 / 184 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60D5CGS1+JME18D2SN1AHRI reference: 217022701 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4015489 → |
CTM60C5CGS1+ furnace: RL18120C16MPS1AHRI reference: 217022721 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4015505 → |
CTM60D5CGS1+ furnace: RL18130D20MPS1AHRI reference: 217022752 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4015532 → |
CTM60C5CGS1+ furnace: RL18080C16MPS1AHRI reference: 217022775 | 16.00 | 8.10 | 26800 | 2.26 | EPA 4015552 → |
CTM60C5CGS1+ furnace: RG19080C16MPS1AHRI reference: 217022784 | 16.00 | 8.10 | 27200 | 2.22 | EPA 4015560 → |
CTM60C5CGS1+ furnace: RG19100C20MPS1AHRI reference: 217022791 | 16.00 | 8.10 | 27400 | 2.22 | EPA 4015567 → |
CTM60C5CGS1+JME12C2SN1AHRI reference: 217022795 | 16.00 | 8.10 | 26800 | 2.26 | EPA 4015568 → |
CTM60C5CGS1+JME16C2SN1AHRI reference: 217022802 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4015574 → |
JSE48D5CG2SS1AHRI reference: 217598328 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4497252 → |
CTM60C5CHS1+ furnace: RG19080C16MPS1AHRI reference: 217020504 | 16.00 | 7.80 | 26800 | 2.30 | EPA 4571273 → |
CTF60C5CHS1+ furnace: RG19080C16MPS1AHRI reference: 217020501 | 16.00 | 7.80 | 26800 | 2.30 | EPA 4571276 → |
JHE60C5CH2SS2AHRI reference: 218457268 | 16.00 | 8.10 | 27200 | 2.34 | EPA 4639418 → |
JHE48C5CG2SS2AHRI reference: 218457262 | 16.00 | 8.00 | 27200 | 2.10 | EPA 4639424 → |
JHE60D5CH2SS2AHRI reference: 218457256 | 16.00 | 8.10 | 27000 | 2.38 | EPA 4639430 → |
JHE48D5CG2SS2AHRI reference: 218457250 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4639436 → |
CTM60D5CHS2+ furnace: RG19120D20MPS1AHRI reference: 218530216 | 16.00 | 8.10 | 27600 | 2.30 | EPA 4648632 → |
CTM60D5CHS2+ furnace: RL18130D20MPS1AHRI reference: 218530202 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4648646 → |
CTM60D5CGS2+ furnace: RL18130D20MPS1AHRI reference: 218530174 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4648668 → |
CTM60C5CHS2+ furnace: RL18100C20MPS1AHRI reference: 218530108 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4648734 → |
CTM60C5CHS2+ furnace: RG19100C20MPS1AHRI reference: 218530098 | 16.00 | 8.10 | 27800 | 2.28 | EPA 4648744 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →