SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity33,000–35,800BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 133 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17133 / 133
EER2 · BTU/Wh11–12133 / 133
HSPF2 · BTU/Wh8–8.5133 / 133
Cooling capacity · BTU/h33,000–35,800133 / 133
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200133 / 133
Heating capacity at 17°F / −8.3°C · BTU/h22,200–23,800133 / 133
Heating capacity at 5°F / −15°C · BTU/h18,000–19,800133 / 133
COP at 5°F / −15°C2–2.48133 / 133
Equipment / loop typeHP - Split System133 / 133
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)133 / 133
Compressor stagingTwo-stage133 / 133
Connected capabilityNo133 / 133

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+ furnace: RL18080C16MPS1AHRI reference: 21701850416.008.10188002.34EPA 4013634
CTM36C5CDS1+ furnace: RL18080C20MPS1AHRI reference: 21701850516.008.10187002.34EPA 4013635
CTM48C5CFS1+ furnace: RL18080C20MPS1AHRI reference: 21701850616.008.50193002.44EPA 4013636
CTM48C5CFS1+JME12C2SN1AHRI reference: 21701850816.008.50190002.46EPA 4013637
CTM36C5CDS1+JME12C2SN1AHRI reference: 21701850916.008.10188002.38EPA 4013638
CTM36C5CDS1+JMET12CS2N1AHRI reference: 21701851016.008.10184002.36EPA 4013639
CTM48C5CFS1+JMET16CS2N1AHRI reference: 21701851116.008.10190002.46EPA 4013640
CTM36C5CDS1+JME16C2SN1AHRI reference: 21701851216.008.10184002.36EPA 4013641
CTM48D5CFS1+JME18D2SN1AHRI reference: 21701851316.008.50190002.46EPA 4013642
CTM48C5CFS1+JMET12CS2N1AHRI reference: 21701851416.008.50193002.44EPA 4013643
CTM36C5CDS1+JMET16CS2N1AHRI reference: 21701851516.008.10184002.36EPA 4013644
CTM48C5CFS1+JME16C2SN1AHRI reference: 21701851616.008.50189002.46EPA 4013645
JHE42C5CF2SS1AHRI reference: 21702051216.008.10190002.46EPA 4013744
JHE36C5CD2SS1AHRI reference: 21702051416.008.10185002.36EPA 4013745
JHE36B5CD2SS1AHRI reference: 21701674716.008.00180002.00EPA 4498119
JHE36B5CD2SS2AHRI reference: 21845721416.008.00180002.00EPA 4622469
JHE36C5CD2SS2AHRI reference: 21845720816.008.10185002.36EPA 4622475
CTF36C5CDS2+ furnace: RL18120C16MPS1AHRI reference: 21852774016.008.10185002.36EPA 4646446
CTF36C5CDS2+ furnace: RG19080C16MPS1AHRI reference: 21852771816.008.10196002.26EPA 4646468
CTF36C5CDS2+ furnace: RL18080C20MPS1AHRI reference: 21852770816.008.10187002.34EPA 4646478

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →