EVCON / AIR-SOURCE HEAT PUMP

RHP15060B21

LX SERIES

19 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–56,500BTU/h

Each efficiency range summarizes published EPA records for RHP15060B21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 19 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1619 / 19
EER2 · BTU/Wh11–1219 / 19
HSPF2 · BTU/Wh7.8–8.119 / 19
Cooling capacity · BTU/h53,000–56,50019 / 19
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,50019 / 19
Heating capacity at 17°F / −8.3°C · BTU/h37,400–38,50019 / 19
Heating capacity at 5°F / −15°C · BTU/h30,600–32,80019 / 19
COP at 5°F / −15°C2.22–2.4619 / 19
Equipment / loop typeHP - Split System19 / 19
Refrigerant / source-reported GWPR-410A (GWP:2088)19 / 19
Compressor stagingTwo-stage19 / 19
Connected capabilityNo19 / 19

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHETD60JBCS2N1AHRI reference: 21254112316.008.10308002.24EPA 2838600 →
JHETD60HBCS2N1AHRI reference: 21254114716.008.10306002.26EPA 2838603 →
JHVTD60JBCC2N1AHRI reference: 21258216116.008.10306002.22EPA 2838620 →
JHVTD60HBCC2N1AHRI reference: 21258217116.008.10306002.28EPA 2838629 →
XAHD60HBCN1+ furnace: RL18130D20MPS1AHRI reference: 21247869915.207.80326002.34EPA 2476870 →
XAHD60HBCN1+ furnace: RL18120C16MPS1AHRI reference: 21247871615.207.80326002.34EPA 2477550 →
XAFC60HBCN1+ furnace: RL18080C16MPS1AHRI reference: 21248001015.207.80310002.34EPA 2482185 →
XAFD60HBCN1+ furnace: RL18080C16MPS1AHRI reference: 21248930115.207.80310002.34EPA 2482420 →
XAHC60HBCN1+ furnace: RL18080C16MPS1AHRI reference: 21247662015.207.80324002.34EPA 2483506 →
XAHC60HBCN1+ furnace: RL18100C20MPS1AHRI reference: 21248601315.207.80328002.34EPA 2485080 →
JHETC60HBCS2N1AHRI reference: 21254116915.207.80306002.22EPA 2838615 →
JHVTC60HBCC2N1AHRI reference: 21258217915.208.10308002.26EPA 2838641 →
XAFC60HBCN1+JME16C2SN1AHRI reference: 21479985715.208.10316002.36EPA 3559629 →
XAFD60HBCN1+JME18D2SN1AHRI reference: 21479986415.208.10318002.40EPA 3559635 →
XAFD60JBCN1+JME18D2SN1AHRI reference: 21479989815.208.10312002.46EPA 3559647 →
XAHD60JBCN1+JME18D2SN1AHRI reference: 21479991015.208.10308002.42EPA 3559659 →
XAHD60JBCN1+ furnace: RG19120D20MPS1AHRI reference: 21464794315.208.10314002.32EPA 3721874 →
XAFD60HBCN1+ furnace: RG19120D20MPS1AHRI reference: 21464793615.207.80316002.34EPA 3721878 →
XAFD60JBCN1+ furnace: RG19120D20MPS1AHRI reference: 21464795015.208.10318002.42EPA 4049207 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →