EVCON / AIR-SOURCE HEAT PUMP

RHP15048B21

LX SERIES · source records, page 2

29 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–46,000BTU/h

Each efficiency range summarizes published EPA records for RHP15048B21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 29 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1629 / 29
EER2 · BTU/Wh11.729 / 29
HSPF2 · BTU/Wh7.8–8.129 / 29
Cooling capacity · BTU/h44,500–46,00029 / 29
Heating capacity at 47°F / 8.3°C · BTU/h43,500–45,50029 / 29
Heating capacity at 17°F / −8.3°C · BTU/h29,400–30,80029 / 29
Heating capacity at 5°F / −15°C · BTU/h23,600–25,40029 / 29
COP at 5°F / −15°C2.24–2.4629 / 29
Equipment / loop typeHP - Split System29 / 29
Refrigerant / source-reported GWPR-410A (GWP:2088)29 / 29
Compressor stagingTwo-stage29 / 29
Connected capabilityNo29 / 29

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC60HXXN1+TXV+ furnace: TM8Y080C16MP11AHRI reference: 21034865415.207.80238002.28EPA 3985021
XAFD60HXXN1+TXV+ furnace: RGF19100CE16MP13AHRI reference: 21034860015.207.80238002.28EPA 3986984
XAHD60GXXN1+TXV+ furnace: TM9Y120D20MP11AHRI reference: 21034716515.207.80236002.24EPA 3988064
XAHC60GXXN1+TXV+ furnace: RGF19080CE20MP13AHRI reference: 21034734115.207.80240002.26EPA 3988095
XAHD60GXXN1+TXV+ furnace: TM8Y100C16MP11AHRI reference: 21034737215.207.80236002.24EPA 3988104
XAHD60GXXN1+TXV+ furnace: RGF1L100CE20MP12AHRI reference: 21034755415.207.80240002.24EPA 3988119
XAFD60HXXN1+TXV+ furnace: TM9Y120D20MP11AHRI reference: 21034760215.207.80238002.28EPA 3988136
XAFC60HXXN1+TXV+ furnace: RGF19080CE20MP13AHRI reference: 21034861815.207.80238002.26EPA 3988795
XAHC60GBCN1+ furnace: RG19100C16MPS1AHRI reference: 21241674615.207.80252002.36EPA 3990706

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →