Coleman / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 4

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60D5CGS2+JME18D2SN2Cold climate designationAHRI reference: 21864214317.508.50360002.32EPA 4665562 →
CTM60D5CGS2+JMC20D2SN1AHRI reference: 21864213717.508.10352002.30EPA 4665568 →
CTF60D5CGS2+JMC20D2SN1AHRI reference: 21864212417.508.10348002.28EPA 4665581 →
JSE48D5CG2SS1AHRI reference: 21864211917.508.10342002.26EPA 4665586 →
JHC48D5CG2SS1AHRI reference: 21864211417.508.10342002.26EPA 4665591 →
JSC48D5CG2SS1AHRI reference: 21864211017.508.10342002.26EPA 4665595 →
CTM60C5CGS2+JMC17C2SN1AHRI reference: 21864210617.508.10342002.26EPA 4665599 →
CTM60C5CGS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21864209417.508.10342002.24EPA 4665611 →
CTM60C5CGS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21864208217.508.10346002.26EPA 4665623 →
CTM60C5CGS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21864207817.508.10346002.26EPA 4665627 →
CTU60C5XGS2+TXV+ furnace: Z8ET100C16LMPS1AHRI reference: 21864207417.508.10336002.22EPA 4665631 →
CTF60C5CGS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21864207017.508.10336002.22EPA 4665635 →
CTU60C5XGS2+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21864205817.508.10346002.26EPA 4665647 →
CTU60C5XGS2+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21864205417.508.10346002.26EPA 4665651 →
CTF60C5CGS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21864205017.508.10346002.26EPA 4665655 →
CTF60C5CGS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21864204617.508.10346002.26EPA 4665659 →
CTU60C5XGS2+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21864203417.508.10338002.24EPA 4665671 →
CTF60C5CGS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21864203017.508.10338002.24EPA 4665675 →
CTU60C5XGS2+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21864202617.508.10340002.22EPA 4665679 →
CTF60C5CGS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21864202217.508.10340002.22EPA 4665683 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →