Coleman / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 5

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CGS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21864201017.508.10338002.24EPA 4665695
CTM60C5CGS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21864200617.508.10338002.24EPA 4665699
CTM60C5CGS2+JME16C2SN2AHRI reference: 21864200217.508.10352002.28EPA 4665703
CTM60C5CGS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21864195417.508.10342002.24EPA 4665751
CTM60C5CGS2+ furnace: Z8ES080C16SMPS1AHRI reference: 21864195017.508.10342002.24EPA 4665755
CTM60C5CGS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21864194617.508.10338002.22EPA 4665759
CTM60C5CGS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21864194217.508.10338002.22EPA 4665763
JSC48C5CG2SS1Cold climate designationAHRI reference: 21864193817.508.50340002.20EPA 4665767
CTU60C5XGS2+TXV+ furnace: TM9E080C16MP12AHRI reference: 21868945817.508.10352002.20EPA 4677891
CTF60C5CGS2+ furnace: TM9E080C16MP12AHRI reference: 21868945717.508.10352002.20EPA 4677892
CTM60C5CGS2+ furnace: TM9E080C16MP12AHRI reference: 21868945617.508.10352002.20EPA 4677893
CTM60C5CGS2+ furnace: TM9E100C16MP12AHRI reference: 21868945317.508.10354002.22EPA 4677896
CTM60C5CGS2+ furnace: TL8E100C20UH11AHRI reference: 21868941917.508.10350002.26EPA 4677915
CTU60C5XGS2+TXV+ furnace: TM8V120C20MP12AHRI reference: 21868941517.508.10340002.20EPA 4677919
CTF60C5CGS2+ furnace: TM8V120C20MP12AHRI reference: 21868941417.508.10340002.20EPA 4677920
CTF60C5CGS2+ furnace: TM8V100C20MP12AHRI reference: 21868941317.508.10340002.20EPA 4677921
CTU60C5XGS2+TXV+ furnace: TM8V100C20MP12AHRI reference: 21868941217.508.10340002.20EPA 4677922
CTM60C5CGS2+ furnace: TM8V120C20MP12AHRI reference: 21868941117.508.10338002.20EPA 4677923
CTM60C5CGS2+ furnace: TMLV120C20MP12AHRI reference: 21868940617.508.10338002.20EPA 4677924
CTU60C5XGS2+TXV+ furnace: TMLV120C20MP12AHRI reference: 21868940517.508.10340002.20EPA 4677925

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →