HH860E2S12
LX SERIES · source records, page 3
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11–12 | 407 / 407 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 43,500–54,000 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–53,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 40,000–45,500 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,600–40,000 | 407 / 407 |
| COP at 5°F / −15°C | 2–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60C5XGS2+TXV+ furnace: Z8ET080C16LMPS1AHRI reference: 218642303 | 17.50 | 8.10 | 34200 | 2.24 | EPA 4665402 → |
CTF60C5CGS2+ furnace: Z8ET080C16LMPS1AHRI reference: 218642297 | 17.50 | 8.10 | 34200 | 2.24 | EPA 4665408 → |
CTM60C5CGS2+JME12C2SN2AHRI reference: 218642291 | 17.50 | 8.10 | 34200 | 2.24 | EPA 4665414 → |
CTM60C5CGS2+ furnace: Z9ES080C16SMPS1AHRI reference: 218642284 | 17.50 | 8.10 | 34600 | 2.22 | EPA 4665421 → |
CTM60C5CGS2+ furnace: Z9ET080C16SMPS1AHRI reference: 218642278 | 17.50 | 8.10 | 34600 | 2.22 | EPA 4665427 → |
CTM60C5CGS2+ furnace: Z8ET080C16LMPS1AHRI reference: 218642272 | 17.50 | 8.10 | 34200 | 2.24 | EPA 4665433 → |
CTM60C5CGS2+JMC16C2SN1AHRI reference: 218642265 | 17.50 | 8.10 | 33800 | 2.24 | EPA 4665440 → |
CTM60C5CGS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218642259 | 17.50 | 8.10 | 34000 | 2.24 | EPA 4665446 → |
CTU60C5XGS2+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 218642246 | 17.50 | 8.10 | 34000 | 2.24 | EPA 4665459 → |
CTF60C5CGS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218642240 | 17.50 | 8.10 | 34000 | 2.24 | EPA 4665465 → |
CTU60C5XGS2+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 218642234 | 17.50 | 8.10 | 34000 | 2.22 | EPA 4665471 → |
CTU60C5XGS2+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 218642228 | 17.50 | 8.10 | 34000 | 2.22 | EPA 4665477 → |
CTF60C5CGS2+ furnace: Z8ES080C20LMPS1AHRI reference: 218642222 | 17.50 | 8.10 | 34000 | 2.22 | EPA 4665483 → |
CTF60C5CGS2+ furnace: Z8ES080C20SMPS1AHRI reference: 218642216 | 17.50 | 8.10 | 34000 | 2.22 | EPA 4665489 → |
CTU60C5XGS2+JMC16C2SN1+TXVAHRI reference: 218642211 | 17.50 | 8.10 | 34200 | 2.26 | EPA 4665494 → |
CTF60C5CGS2+JMC16C2SN1AHRI reference: 218642205 | 17.50 | 8.10 | 34200 | 2.26 | EPA 4665500 → |
CTU60C5XGS2+JME16C2SN2+TXVAHRI reference: 218642174 | 17.50 | 8.10 | 35200 | 2.28 | EPA 4665531 → |
CTF60C5CGS2+JME16C2SN2AHRI reference: 218642168 | 17.50 | 8.10 | 35200 | 2.28 | EPA 4665537 → |
CTM60C5CGS2+ furnace: Z8VT100C16SMPC1AHRI reference: 218642162 | 17.50 | 8.10 | 34000 | 2.22 | EPA 4665543 → |
CTM60D5CGS2+JME18D2SN2AHRI reference: 218642155 | 17.50 | 8.10 | 34800 | 2.28 | EPA 4665550 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →