Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 222 / 222 |
| EER2 · BTU/Wh | 11–12 | 222 / 222 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 222 / 222 |
| Cooling capacity · BTU/h | 52,500–55,000 | 222 / 222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,000–60,000 | 222 / 222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,800–39,500 | 222 / 222 |
| Heating capacity at 5°F / −15°C · BTU/h | 30,000–32,600 | 222 / 222 |
| COP at 5°F / −15°C | 2–2.38 | 222 / 222 |
| Equipment / loop type | HP - Split System | 222 / 222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 222 / 222 |
| Compressor staging | Two-stage | 222 / 222 |
| Connected capability | No | 222 / 222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60D5CHS2+ furnace: Z9ET120D20SMPS1AHRI reference: 218529024 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647092 → |
CTM60D5CHS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218529018 | 15.20 | 8.10 | 31400 | 2.28 | EPA 4647098 → |
CTM60D5CHS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218529014 | 15.20 | 8.10 | 31400 | 2.28 | EPA 4647102 → |
CTM60D5CHS2+JMC20D2SN1AHRI reference: 218529010 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4647106 → |
CTM60D5CHS2+JMVT20DC2N1AHRI reference: 218529006 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4647110 → |
CTM60C5CHS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218529002 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647114 → |
CTM60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218528998 | 15.20 | 8.10 | 32400 | 2.24 | EPA 4647118 → |
CTM60C5CHS2+ furnace: TP9C100C16MP13AHRI reference: 218528992 | 15.20 | 8.00 | 30800 | 2.00 | EPA 4647124 → |
CTM60C5CHS2+ furnace: TM9V100C16MP12AHRI reference: 218528988 | 15.20 | 8.00 | 30800 | 2.00 | EPA 4647128 → |
CTM60C5CHS2+ furnace: TP9C100C20MP13AHRI reference: 218528982 | 15.20 | 8.00 | 30800 | 2.00 | EPA 4647134 → |
CTM60C5CHS2+ furnace: TM9V100C20MP12AHRI reference: 218528978 | 15.20 | 8.00 | 30800 | 2.00 | EPA 4647138 → |
CTM60C5CHS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218528974 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647142 → |
CTM60C5CHS2+ furnace: Z8VT100C16SMPC1AHRI reference: 218528970 | 15.20 | 8.10 | 31400 | 2.26 | EPA 4647146 → |
CTM60C5CHS2+JMC16C2SN1AHRI reference: 218528966 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4647150 → |
CTM60C5CHS2+JMVT16CC2N1AHRI reference: 218528962 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4647154 → |
CTM60C5CHS2+JMVT17CC2N1AHRI reference: 218528958 | 15.20 | 8.10 | 31000 | 2.30 | EPA 4647158 → |
CTM60C5CHS2+ furnace: Z8ET100C20LMPS1AHRI reference: 218528954 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4647162 → |
CTM60C5CHS2+ furnace: Z8ES120C20LMPS1AHRI reference: 218528948 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647168 → |
CTM60C5CHS2+ furnace: Z8ES120C20SMPS1AHRI reference: 218528944 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647172 → |
CTM60C5CHS2+ furnace: Z8ES100C16LMPS1AHRI reference: 218528938 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647178 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →