SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity52,500–55,000BTU/h

Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16222 / 222
EER2 · BTU/Wh11–12222 / 222
HSPF2 · BTU/Wh7.8–8.5222 / 222
Cooling capacity · BTU/h52,500–55,000222 / 222
Heating capacity at 47°F / 8.3°C · BTU/h56,000–60,000222 / 222
Heating capacity at 17°F / −8.3°C · BTU/h37,800–39,500222 / 222
Heating capacity at 5°F / −15°C · BTU/h30,000–32,600222 / 222
COP at 5°F / −15°C2–2.38222 / 222
Equipment / loop typeHP - Split System222 / 222
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)222 / 222
Compressor stagingTwo-stage222 / 222
Connected capabilityNo222 / 222

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60D5CJS1+ furnace: Z9ES120D20SMPS1AHRI reference: 21701788415.208.10324002.32EPA 4571899
CTF60C5CHS1+JMVT17CC2N1AHRI reference: 21701786415.208.10312002.28EPA 4571914
CTF60C5CHS1+JMC16C2SN1AHRI reference: 21701785515.208.10312002.28EPA 4571922
CTF60C5CHS1+ furnace: Z9ES100C20SMPS1AHRI reference: 21701785115.208.10316002.26EPA 4571925
CTF60D5CHS1+JMC20D2SN1AHRI reference: 21701784815.208.10310002.30EPA 4571928
CTF60D5CHS1+ furnace: Z9ES120D20SMPS1AHRI reference: 21701784215.208.10316002.26EPA 4571931
CTF60C5CHS1+JME16C2SN1AHRI reference: 21701782215.208.10312002.30EPA 4571947
CTF60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21701781715.208.10312002.28EPA 4571949
CTF60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21701780815.208.10314002.28EPA 4571957
CTF60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21701780715.208.10314002.28EPA 4571958
CTF60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21701780615.208.00318002.24EPA 4571959
CTF60C5CHS1+JMC17C2SN1AHRI reference: 21701779415.208.10312002.28EPA 4571970
CTU60D5XHS1+JME18D2SN1+TXVAHRI reference: 21701777815.208.10312002.30EPA 4571981
CTM60D5CJS2+ furnace: Z9ES120D20SMPS1AHRI reference: 21852908215.208.50326002.32EPA 4647040
CTM60D5CJS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21852907815.208.10324002.32EPA 4647044
CTM60D5CJS2+ furnace: TP9C120D20MP13AHRI reference: 21852904815.208.00314002.00EPA 4647068
CTM60D5CJS2+ furnace: TM9V120D20MP12AHRI reference: 21852904415.208.00314002.00EPA 4647072
CTM60D5CHS2+ furnace: TP9C120D20MP13AHRI reference: 21852903815.208.00304002.00EPA 4647078
CTM60D5CHS2+ furnace: TM9V120D20MP12AHRI reference: 21852903415.208.00304002.00EPA 4647082
CTM60D5CHS2+ furnace: Z9ES120D20SMPS1AHRI reference: 21852902815.208.10316002.26EPA 4647088