CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH660E2S11

LX SERIES · source records, page 9

222 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity52,500–55,000BTU/h

Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16222 / 222
EER2 · BTU/Wh11–12222 / 222
HSPF2 · BTU/Wh7.8–8.5222 / 222
Cooling capacity · BTU/h52,500–55,000222 / 222
Heating capacity at 47°F / 8.3°C · BTU/h56,000–60,000222 / 222
Heating capacity at 17°F / −8.3°C · BTU/h37,800–39,500222 / 222
Heating capacity at 5°F / −15°C · BTU/h30,000–32,600222 / 222
COP at 5°F / −15°C2–2.38222 / 222
Equipment / loop typeHP - Split System222 / 222
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)222 / 222
Compressor stagingTwo-stage222 / 222
Connected capabilityNo222 / 222

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CHS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21852893415.208.10316002.26EPA 4647182 →
CTM60C5CHS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21852893015.208.10314002.26EPA 4647186 →
CTM60C5CHS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21852892415.208.10316002.26EPA 4647192 →
CTM60C5CHS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21852892015.208.10312002.28EPA 4647196 →
CTM60C5CHS2+ furnace: Z8ES080C20LMPS1AHRI reference: 21852891415.208.10316002.26EPA 4647202 →
CTM60C5CHS2+ furnace: Z8ES080C20SMPS1AHRI reference: 21852891015.208.10316002.26EPA 4647206 →
CTM60C5CHS2+JMC17C2SN1AHRI reference: 21852890615.208.10310002.30EPA 4647210 →
CTM60C5CHS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21852890215.208.10318002.24EPA 4647214 →
CTM60C5CHS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21852889815.208.10320002.24EPA 4647218 →
CTM60C5CHS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21852889215.208.10320002.24EPA 4647224 →
CTM60C5CHS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852888615.208.10314002.26EPA 4647230 →
CTM60C5CHS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852888215.208.10314002.26EPA 4647234 →
CTM60C5CHS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21852887815.208.10318002.24EPA 4647238 →
CTM60C5CHS2+ furnace: Z8ES100C20LMPS1AHRI reference: 21852887215.208.10312002.28EPA 4647244 →
CTM60C5CHS2+ furnace: Z8ES100C20SMPS1AHRI reference: 21852886815.208.10312002.28EPA 4647248 →
CTM60C5CHS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852886215.207.80318002.24EPA 4647254 →
CTM60C5CHS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21852885615.208.10320002.22EPA 4647260 →
CTF60D5CJS2+ furnace: TP9C120D20MP13AHRI reference: 21852884415.208.00312002.00EPA 4647266 →
CTF60D5CJS2+ furnace: TM9V120D20MP12AHRI reference: 21852884015.208.00312002.00EPA 4647270 →
CTF60D5CJS2+ furnace: Z9ES120D20SMPS1AHRI reference: 21852883415.208.10324002.32EPA 4647276 →