XH548E2S11
LX SERIES · source records, page 7
359 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 359 / 359 |
| EER2 · BTU/Wh | 11–12 | 359 / 359 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 359 / 359 |
| Cooling capacity · BTU/h | 44,500–48,000 | 359 / 359 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 359 / 359 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 359 / 359 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 359 / 359 |
| COP at 5°F / −15°C | 2.1–2.42 | 359 / 359 |
| Equipment / loop type | HP - Split System | 359 / 359 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 359 / 359 |
| Compressor staging | Two-stage | 359 / 359 |
| Connected capability | No | 359 / 359 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60D5XGS1+JMC20D2SN1+TXVAHRI reference: 214807985 | 15.20 | 7.80 | 24600 | 2.28 | EPA 3992566 → |
CTU60C5XGS1+JME16C2SN1+TXVAHRI reference: 214807990 | 15.20 | 7.80 | 25000 | 2.26 | EPA 3992571 → |
CTU60D5XGS1+JME18D2SN1+TXVAHRI reference: 214807995 | 15.20 | 7.80 | 25000 | 2.26 | EPA 3992574 → |
CTU60D5XHS1+JMET18DS2N1+TXVAHRI reference: 214808188 | 15.20 | 8.10 | 26000 | 2.40 | EPA 3992586 → |
CTU60D5XGS1+JMET18DS2N1+TXVAHRI reference: 214808012 | 15.20 | 7.80 | 25000 | 2.26 | EPA 3992593 → |
CTU60D5XHS1+JMC20D2SN1+TXVAHRI reference: 214808198 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3992599 → |
CTU60D5XHS1+JME18D2SN1+TXVAHRI reference: 214808203 | 15.20 | 8.10 | 26000 | 2.42 | EPA 3992602 → |
CTU60D5XHS1+JMVT20DC2N1+TXVAHRI reference: 214808193 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3992603 → |
CTM60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 216782947 | 15.20 | 8.10 | 26400 | 2.40 | EPA 4046910 → |
CTM60C5CHS1+ furnace: Z8ES080C20LMPS1AHRI reference: 216783609 | 15.20 | 8.10 | 26200 | 2.40 | EPA 4047040 → |
CTF60C5CHS1+ furnace: Z8ES120C16LMPS1AHRI reference: 216782336 | 15.20 | 8.10 | 26400 | 2.36 | EPA 4047065 → |
CTM60C5CHS1+ furnace: Z8ES120C16LMPS1AHRI reference: 216782918 | 15.20 | 8.10 | 26400 | 2.38 | EPA 4047069 → |
CTM60C5CHS1+ furnace: Z8ES100C16LMPS1AHRI reference: 216782933 | 15.20 | 8.10 | 26600 | 2.36 | EPA 4047074 → |
CTF60C5CHS1+ furnace: Z8ES100C20LMPS1AHRI reference: 216785026 | 15.20 | 8.10 | 26200 | 2.38 | EPA 4047084 → |
CTF60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 216785041 | 15.20 | 8.10 | 26600 | 2.38 | EPA 4047091 → |
CTM60C5CHS1+ furnace: Z8ES100C20LMPS1AHRI reference: 216786029 | 15.20 | 8.10 | 26200 | 2.40 | EPA 4047096 → |
CTM60C5CHS1+ furnace: Z8ES120C20LMPS1AHRI reference: 216786507 | 15.20 | 8.10 | 26200 | 2.38 | EPA 4047101 → |
CTU60D5XHS1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 216785056 | 15.20 | 8.10 | 26600 | 2.38 | EPA 4047117 → |
CTM60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 214605457 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570763 → |
CTM60C5CGS1+JMC16C2SN1AHRI reference: 214429106 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570786 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →