CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 6

359 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16359 / 359
EER2 · BTU/Wh11–12359 / 359
HSPF2 · BTU/Wh7.8–8.1359 / 359
Cooling capacity · BTU/h44,500–48,000359 / 359
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000359 / 359
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400359 / 359
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200359 / 359
COP at 5°F / −15°C2.1–2.42359 / 359
Equipment / loop typeHP - Split System359 / 359
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)359 / 359
Compressor stagingTwo-stage359 / 359
Connected capabilityNo359 / 359

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS1+JME12C2SN1AHRI reference: 21443190315.207.80258002.40EPA 3992078
CTF60C5CHS1+JMVT16CC2N1AHRI reference: 21443193415.207.80262002.40EPA 3992081
CTF60C5CHS1+JMET12CS2N1AHRI reference: 21443200115.207.80258002.40EPA 3992087
CTF60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21637691015.207.80266002.34EPA 3992224
CTF60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21637693915.207.80264002.34EPA 3992231
CTF60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21637696815.207.80262002.34EPA 3992240
CTF60D5CHS1+ furnace: Z9ET120D20SMPS1AHRI reference: 21637699715.207.80260002.38EPA 3992248
CTU60D5XHS1+TXV+ furnace: Z9ET120D20SMPS1AHRI reference: 21637702715.207.80260002.38EPA 3992256
CTF60C5CHS1+ furnace: Z9ES080C20SMPS1AHRI reference: 21460523715.207.80258002.36EPA 3992263
CTF60D5CHS1+ furnace: Z9ES120D20SMPS1AHRI reference: 21460525715.207.80258002.38EPA 3992268
CTF60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460560215.208.10264002.36EPA 3992272
CTF60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21460560715.207.80260002.36EPA 3992280
CTF60C5CHS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460566715.207.80260002.38EPA 3992282
CTF60C5CHS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21460567215.207.80262002.36EPA 3992288
CTF60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21460574215.208.10266002.38EPA 3992293
CTF60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21460578215.207.80262002.36EPA 3992298
CTF60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21460578715.208.10262002.38EPA 3992301
CTU60D5XHS1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 21465035015.208.10266002.38EPA 3992368
CTU60D5XHS1+TXV+ furnace: Z9ES120D20SMPS1AHRI reference: 21465069815.207.80258002.38EPA 3992374
CTU60D5XGS1+JMVT20DC2N1+TXVAHRI reference: 21480797015.207.80246002.28EPA 3992552