CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 8

359 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16359 / 359
EER2 · BTU/Wh11–12359 / 359
HSPF2 · BTU/Wh7.8–8.1359 / 359
Cooling capacity · BTU/h44,500–48,000359 / 359
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000359 / 359
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400359 / 359
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200359 / 359
COP at 5°F / −15°C2.1–2.42359 / 359
Equipment / loop typeHP - Split System359 / 359
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)359 / 359
Compressor stagingTwo-stage359 / 359
Connected capabilityNo359 / 359

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CGS1+JMET16CS2N1AHRI reference: 21442890115.207.80252002.24EPA 4570791 →
CTM60D5CGS1+JMET18DS2N1AHRI reference: 21442735115.207.80254002.28EPA 4570806 →
CTF60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744483115.207.80262002.38EPA 4571178 →
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744482915.207.80262002.38EPA 4571180 →
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744482615.207.80264002.40EPA 4571183 →
CTU60C5XGS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21744482215.207.80256002.28EPA 4571186 →
CTF60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744482115.207.80256002.28EPA 4571187 →
CTM60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744481515.207.80256002.28EPA 4571188 →
CTU60C5XGS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21744481415.207.80258002.26EPA 4571189 →
CTF60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744481315.207.80258002.26EPA 4571190 →
CTM60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744481215.207.80258002.26EPA 4571191 →
CTM60C5CGS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21678629815.207.80260002.26EPA 4572125 →
CTF60C5CHS1+ furnace: Z8ES080C16LMPS1AHRI reference: 21678605915.207.80262002.36EPA 4572130 →
CTF60C5CHS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21678604415.207.80260002.38EPA 4572135 →
CTU60C5XGS1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21678585415.207.80258002.20EPA 4572140 →
CTF60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678584015.207.80258002.20EPA 4572145 →
CTM60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678582615.207.80258002.26EPA 4572150 →
CTU60C5XGS1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21678581115.207.80254002.24EPA 4572155 →
CTF60C5CGS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21678579615.207.80254002.24EPA 4572160 →
CTM60D5CGS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21678522215.207.80256002.28EPA 4572165 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.