CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 8

359 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16359 / 359
EER2 · BTU/Wh11–12359 / 359
HSPF2 · BTU/Wh7.8–8.1359 / 359
Cooling capacity · BTU/h44,500–48,000359 / 359
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000359 / 359
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400359 / 359
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200359 / 359
COP at 5°F / −15°C2.1–2.42359 / 359
Equipment / loop typeHP - Split System359 / 359
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)359 / 359
Compressor stagingTwo-stage359 / 359
Connected capabilityNo359 / 359

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CGS1+JMET16CS2N1AHRI reference: 21442890115.207.80252002.24EPA 4570791
CTM60D5CGS1+JMET18DS2N1AHRI reference: 21442735115.207.80254002.28EPA 4570806
CTF60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744483115.207.80262002.38EPA 4571178
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744482915.207.80262002.38EPA 4571180
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744482615.207.80264002.40EPA 4571183
CTU60C5XGS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21744482215.207.80256002.28EPA 4571186
CTF60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744482115.207.80256002.28EPA 4571187
CTM60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744481515.207.80256002.28EPA 4571188
CTU60C5XGS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21744481415.207.80258002.26EPA 4571189
CTF60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744481315.207.80258002.26EPA 4571190
CTM60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744481215.207.80258002.26EPA 4571191
CTM60C5CGS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21678629815.207.80260002.26EPA 4572125
CTF60C5CHS1+ furnace: Z8ES080C16LMPS1AHRI reference: 21678605915.207.80262002.36EPA 4572130
CTF60C5CHS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21678604415.207.80260002.38EPA 4572135
CTU60C5XGS1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21678585415.207.80258002.20EPA 4572140
CTF60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678584015.207.80258002.20EPA 4572145
CTM60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678582615.207.80258002.26EPA 4572150
CTU60C5XGS1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21678581115.207.80254002.24EPA 4572155
CTF60C5CGS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21678579615.207.80254002.24EPA 4572160
CTM60D5CGS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21678522215.207.80256002.28EPA 4572165