XH548E2S11
LX SERIES · source records, page 5
359 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 359 / 359 |
| EER2 · BTU/Wh | 11–12 | 359 / 359 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 359 / 359 |
| Cooling capacity · BTU/h | 44,500–48,000 | 359 / 359 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 359 / 359 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 359 / 359 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 359 / 359 |
| COP at 5°F / −15°C | 2.1–2.42 | 359 / 359 |
| Equipment / loop type | HP - Split System | 359 / 359 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 359 / 359 |
| Compressor staging | Two-stage | 359 / 359 |
| Connected capability | No | 359 / 359 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60D5CHS1+ furnace: TM9V120D20MP12AHRI reference: 214429155 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3991862 → |
CTF60D5CGS1+JMC20D2SN1AHRI reference: 214425825 | 15.20 | 7.80 | 24600 | 2.28 | EPA 3991876 → |
CTF60C5CHS1+ furnace: TL8E100C20UH11AHRI reference: 214425864 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3991880 → |
CTF60D5CHS1+JMC20D2SN1AHRI reference: 214426064 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3991898 → |
CTF60C5CHS1+JMVT17CC2N1AHRI reference: 214426650 | 15.20 | 7.80 | 26200 | 2.40 | EPA 3991908 → |
CTF60C5CHS1+JMC16C2SN1AHRI reference: 214426659 | 15.20 | 7.80 | 26200 | 2.40 | EPA 3991914 → |
CTM60C5CHS1+ furnace: TL8E100C20UH11AHRI reference: 214426668 | 15.20 | 7.80 | 25800 | 2.38 | EPA 3991918 → |
CTF60C5CHS1+JMET16CS2N1AHRI reference: 214428302 | 15.20 | 8.10 | 26200 | 2.38 | EPA 3991937 → |
CTF60D5CGS1+JMET18DS2N1AHRI reference: 214428374 | 15.20 | 7.80 | 25000 | 2.26 | EPA 3991940 → |
CTF60D5CHS1+JME18D2SN1AHRI reference: 214428623 | 15.20 | 8.10 | 26000 | 2.42 | EPA 3991949 → |
CTM60C5CHS1+ furnace: TL9E100C20UH11AHRI reference: 214428628 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3991954 → |
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 214427143 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3992004 → |
CTM60C5CHS1+ furnace: TM9V100C16MP12AHRI reference: 214427361 | 15.20 | 7.80 | 26000 | 2.36 | EPA 3992012 → |
CTM60C5CHS1+ furnace: TP9C100C16MP13AHRI reference: 214427366 | 15.20 | 7.80 | 26000 | 2.36 | EPA 3992017 → |
CTF60D5CHS1+JMET18DS2N1AHRI reference: 214427407 | 15.20 | 8.10 | 26000 | 2.40 | EPA 3992023 → |
CTF60C5CGS1+JME16C2SN1AHRI reference: 214427437 | 15.20 | 7.80 | 25000 | 2.26 | EPA 3992028 → |
CTM60C5CHS1+ furnace: TM8V120C20MP12AHRI reference: 214427476 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3992031 → |
CTM60C5CHS1+ furnace: TM8V100C20MP12AHRI reference: 214427481 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3992037 → |
CTM60C5CHS1+ furnace: TPLC100C20MP13AHRI reference: 214427491 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3992046 → |
CTF60C5CHS1+JME16C2SN1AHRI reference: 214427578 | 15.20 | 8.10 | 26000 | 2.40 | EPA 3992060 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.