Century / AIR-SOURCE HEAT PUMP

HRG1530S1R-**A

HRG15 SERIES · HRG15 Series · source records, page 2

78 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for HRG1530S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.278 / 78
EER2 · BTU/Wh12.5–13.578 / 78
HSPF2 · BTU/Wh7.8–8.678 / 78
Cooling capacity · BTU/h28,200–30,00078 / 78
Heating capacity at 47°F / 8.3°C · BTU/h27,200–30,00078 / 78
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,60078 / 78
Heating capacity at 5°F / −15°C · BTU/h13,400–15,40078 / 78
COP at 5°F / −15°C1.96–2.3478 / 78
Equipment / loop typeHP - Split System78 / 78
Refrigerant / source-reported GWPR-410A (GWP:2088)78 / 78
Compressor stagingSingle stage78 / 78
Connected capabilityNo78 / 78

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P36A+TDR+TXV+ furnace: GUH92C045B3MAHRI reference: 21033135915.808.10143002.26EPA 2456348 →
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C070B3MAHRI reference: 21033135115.808.00144002.22EPA 2457324 →
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C045A3MAHRI reference: 21033134415.808.00141002.20EPA 2457737 →
EAD4X-42B+TDR+ furnace: GDD80C070B3MAHRI reference: 21326542915.808.60153002.34EPA 2839997 →
EAD4X-42B+TDR+ furnace: GDD92C045B3MAHRI reference: 21326543115.808.60153002.34EPA 2839998 →
EAD4X-42B+TDR+ furnace: GDD92C070B3MAHRI reference: 21326543215.808.60153002.32EPA 2840054 →
7EC36BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 21471680315.808.10143002.26EPA 3491267 →
7EH36CX-0*+TDR+ furnace: GUH80C090C5MAHRI reference: 21471676315.808.50148002.26EPA 3491285 →
7EH36CX-0*+TDR+ furnace: GUH92C110C4MAHRI reference: 21471676715.808.30147002.24EPA 3491289 →
7EC30AX-0*+TDR+ furnace: GUH80C045A3MAHRI reference: 21471678415.808.00141002.20EPA 3491362 →
7EC36AX-0*+TDR+ furnace: GUH80X040A3MAHRI reference: 21471679515.808.00144002.26EPA 3491372 →
7EC30BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471678715.808.00144002.22EPA 3491373 →
7EC36AX-0*+TDR+ furnace: GUH80X060A3MAHRI reference: 21471679615.808.00144002.26EPA 3491374 →
7EH30BX-0*+TDR+ furnace: GUH80X080B4MAHRI reference: 21471675415.807.80136002.08EPA 3491447 →
7ED42BX-0*+TDR+ furnace: GDD92C045B3MAHRI reference: 21471677815.808.60153002.34EPA 3491489 →
7EH30BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 21471675715.807.80136002.10EPA 3491519 →
7EH30BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 21471676115.808.00137002.08EPA 3491523 →
7ED42BX-0*+TDR+ furnace: GDD80C070B3MAHRI reference: 21471677615.808.60153002.34EPA 3491776 →
7ED42BX-0*+TDR+ furnace: GDD92C070B3MAHRI reference: 21471677915.808.60153002.32EPA 3491897 →
EA(C;U)1P30A+TDR+TXV+ furnace: GUH92C070B3MAHRI reference: 21033134815.608.00144002.20EPA 2456089 →