HRG1530S1R-**A
HRG15 SERIES · HRG15 Series · source records, page 3
78 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HRG1530S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.2 | 78 / 78 |
| EER2 · BTU/Wh | 12.5–13.5 | 78 / 78 |
| HSPF2 · BTU/Wh | 7.8–8.6 | 78 / 78 |
| Cooling capacity · BTU/h | 28,200–30,000 | 78 / 78 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 27,200–30,000 | 78 / 78 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,400–19,600 | 78 / 78 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–15,400 | 78 / 78 |
| COP at 5°F / −15°C | 1.96–2.34 | 78 / 78 |
| Equipment / loop type | HP - Split System | 78 / 78 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 78 / 78 |
| Compressor staging | Single stage | 78 / 78 |
| Connected capability | No | 78 / 78 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA(C;U)1P36A+TDR+TXV+ furnace: GUH96C070B3MAHRI reference: 210331362 | 15.60 | 8.10 | 14300 | 2.26 | EPA 2456338 → |
EA(C;U)1P36A+TDR+TXV+ furnace: GUH96C045B3MAHRI reference: 210331361 | 15.60 | 8.10 | 14600 | 2.26 | EPA 2456740 → |
EA(C;U)1P30A+TDR+TXV+ furnace: GUH97M070B3MAHRI reference: 210331354 | 15.60 | 8.00 | 14500 | 2.18 | EPA 2457362 → |
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C070A3MAHRI reference: 210331345 | 15.60 | 8.00 | 14400 | 2.20 | EPA 2457940 → |
EA(C;U)1P30A+TDR+TXV+ furnace: GUH92C045B3MAHRI reference: 210331347 | 15.60 | 8.00 | 14400 | 2.20 | EPA 2458869 → |
EAD4X-42B+TDR+ furnace: GDD96C070B4MAHRI reference: 213265434 | 15.60 | 8.60 | 15300 | 2.32 | EPA 2840037 → |
7EC36BX-0*+TDR+ furnace: GUH96C045B3MAHRI reference: 214716805 | 15.60 | 8.10 | 14600 | 2.26 | EPA 3491269 → |
7EC36BX-0*+TDR+ furnace: GUH96C070B3MAHRI reference: 214716806 | 15.60 | 8.10 | 14300 | 2.26 | EPA 3491270 → |
7EH36CX-0*+TDR+ furnace: GUH80C110C5MAHRI reference: 214716764 | 15.60 | 8.30 | 14600 | 2.22 | EPA 3491286 → |
7EH36CX-0*+TDR+ furnace: GUH92C090C3MAHRI reference: 214716765 | 15.60 | 8.30 | 14700 | 2.24 | EPA 3491287 → |
7EH36CX-0*+TDR+ furnace: GUH92C090C4MAHRI reference: 214716766 | 15.60 | 8.30 | 14600 | 2.24 | EPA 3491288 → |
7EH36CX-0*+TDR+ furnace: GUH92C110C5MAHRI reference: 214716768 | 15.60 | 8.50 | 14800 | 2.24 | EPA 3491290 → |
7EH36CX-0*+TDR+ furnace: GUH96C090C4MAHRI reference: 214716769 | 15.60 | 8.30 | 14500 | 2.22 | EPA 3491291 → |
7EH36CX-0*+TDR+ furnace: GUH96C110C5MAHRI reference: 214716770 | 15.60 | 8.50 | 14800 | 2.26 | EPA 3491292 → |
7ED42BX-0*+TDR+ furnace: GDD96C070B4MAHRI reference: 214716781 | 15.60 | 8.60 | 15300 | 2.32 | EPA 3491359 → |
7EC30AX-0*+TDR+ furnace: GUH80X040A3MAHRI reference: 214716782 | 15.60 | 7.80 | 14200 | 2.20 | EPA 3491360 → |
7EC30AX-0*+TDR+ furnace: GUH80X060A3MAHRI reference: 214716783 | 15.60 | 7.80 | 14200 | 2.20 | EPA 3491361 → |
7EC30AX-0*+TDR+ furnace: GUH80C070A3MAHRI reference: 214716785 | 15.60 | 8.00 | 14400 | 2.20 | EPA 3491363 → |
7EC36BX-0*+TDR+ furnace: GUH80X080B4MAHRI reference: 214716800 | 15.60 | 8.10 | 14600 | 2.24 | EPA 3491377 → |
7EC30BX-0*+TDR+ furnace: GUH92C045B3MAHRI reference: 214716789 | 15.60 | 8.00 | 14400 | 2.20 | EPA 3491396 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →