HRG1530S1R-**A
HRG15 SERIES · HRG15 Series
78 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HRG1530S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.2 | 78 / 78 |
| EER2 · BTU/Wh | 12.5–13.5 | 78 / 78 |
| HSPF2 · BTU/Wh | 7.8–8.6 | 78 / 78 |
| Cooling capacity · BTU/h | 28,200–30,000 | 78 / 78 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 27,200–30,000 | 78 / 78 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,400–19,600 | 78 / 78 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–15,400 | 78 / 78 |
| COP at 5°F / −15°C | 1.96–2.34 | 78 / 78 |
| Equipment / loop type | HP - Split System | 78 / 78 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 78 / 78 |
| Compressor staging | Single stage | 78 / 78 |
| Connected capability | No | 78 / 78 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA(C;U)1P36A+TDR+TXV+ furnace: GUH80C090B4MAHRI reference: 210331358 | 16.20 | 8.10 | 14100 | 2.26 | EPA 2459660 → |
EAD4X-42B+TDR+ furnace: GDD80C090B4MAHRI reference: 213265430 | 16.20 | 8.60 | 14800 | 2.34 | EPA 2840053 → |
7EC36BX-0*+TDR+ furnace: GUH80C090B4MAHRI reference: 214716802 | 16.20 | 8.10 | 14100 | 2.26 | EPA 3491379 → |
7ED42BX-0*+TDR+ furnace: GDD80C090B4MAHRI reference: 214716777 | 16.20 | 8.60 | 14800 | 2.34 | EPA 3491488 → |
7EH30BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 214716755 | 16.20 | 7.80 | 13400 | 2.12 | EPA 3491517 → |
7EH30BX-0*+TDR+ furnace: GUH80C090B4MAHRI reference: 214716756 | 16.20 | 7.80 | 13400 | 2.10 | EPA 3491518 → |
EA(C;U)1P36A+TDR+TXV+ furnace: GUH92C070B3MAHRI reference: 210331360 | 16.00 | 8.10 | 14400 | 2.28 | EPA 2456336 → |
EA(C;U)1P36A+TDR+TXV+ furnace: GUH80C045A3MAHRI reference: 210331356 | 16.00 | 8.10 | 14400 | 2.28 | EPA 2456361 → |
EA(C;U)1P36A+TDR+TXV+ furnace: GUH97M070B3MAHRI reference: 210331366 | 16.00 | 8.10 | 14500 | 2.28 | EPA 2456423 → |
EA(C;U)1P36A+TDR+TXV+ furnace: GUH80C070A3MAHRI reference: 210331357 | 16.00 | 8.10 | 14400 | 2.28 | EPA 2456445 → |
EA(C;U)1P36A+TDR+TXV+ furnace: GUH80C070B3MAHRI reference: 210331363 | 16.00 | 8.10 | 14300 | 2.26 | EPA 2459429 → |
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C090B4MAHRI reference: 210331346 | 16.00 | 8.00 | 14200 | 2.22 | EPA 2459651 → |
7EC36BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 214716804 | 16.00 | 8.10 | 14400 | 2.28 | EPA 3491268 → |
7EC36BX-0*+TDR+ furnace: GUH97M070B3MAHRI reference: 214716807 | 16.00 | 8.10 | 14500 | 2.28 | EPA 3491306 → |
7EC36AX-0*+TDR+ furnace: GUH80C045A3MAHRI reference: 214716797 | 16.00 | 8.10 | 14400 | 2.28 | EPA 3491375 → |
7EC36AX-0*+TDR+ furnace: GUH80C070A3MAHRI reference: 214716798 | 16.00 | 8.10 | 14400 | 2.28 | EPA 3491376 → |
7EC36BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 214716801 | 16.00 | 8.10 | 14300 | 2.26 | EPA 3491378 → |
7EC30BX-0*+TDR+ furnace: GUH80C090B4MAHRI reference: 214716788 | 16.00 | 8.00 | 14200 | 2.22 | EPA 3491383 → |
7EH30BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 214716758 | 16.00 | 7.80 | 13600 | 2.06 | EPA 3491520 → |
HCG36V1PAHRI reference: 211174402 | 15.80 | 8.10 | 13400 | 2.16 | EPA 2454911 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.