GH5SAN524**AA*
15 SEER2 HP · source records, page 7
206 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 206 / 206 |
| EER2 · BTU/Wh | 11.7–13 | 206 / 206 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 206 / 206 |
| Cooling capacity · BTU/h | 22,200–24,400 | 206 / 206 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,600–24,000 | 206 / 206 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 206 / 206 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,800–11,900 | 206 / 206 |
| COP at 5°F / −15°C | 1.96–2.26 | 206 / 206 |
| Equipment / loop type | HP - Split System | 206 / 206 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 206 / 206 |
| Compressor staging | Single stage | 206 / 206 |
| Connected capability | No | 206 / 206 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**2517AM*+ furnace: 58S(B,C)*B090M17**14AHRI reference: 214210404 | 15.50 | 7.80 | 11400 | 2.12 | EPA 3410057 → |
CAA**3721AM*+ furnace: 59TP6C100V21**22AHRI reference: 214212160 | 15.50 | 7.80 | 11500 | 2.16 | EPA 3410158 → |
CVAVA3117XMA*+ furnace: 58S(B,C)*B070M17**12AHRI reference: 214213150 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3410205 → |
CAA**3721AM*+ furnace: 58SU*B040M17**12AHRI reference: 214211283 | 15.50 | 7.80 | 11500 | 2.16 | EPA 3410318 → |
CAA**3721AM*+ furnace: 58SU*B080M21**20AHRI reference: 214211343 | 15.50 | 7.80 | 11400 | 2.16 | EPA 3410573 → |
CVAMA3217XMA*+ furnace: 58S(B,C)*B070M17**16AHRI reference: 214212505 | 15.50 | 7.80 | 11400 | 2.00 | EPA 3411176 → |
CVAMA3217XMA*+ furnace: 58S(B,C)*B070M17**12AHRI reference: 214212475 | 15.50 | 7.80 | 11400 | 2.00 | EPA 3411265 → |
CAA**3717AM*+ furnace: 58SU*B060M17**16AHRI reference: 214210821 | 15.50 | 7.80 | 11200 | 2.10 | EPA 3411392 → |
CVAMA3217XMA*+ furnace: 58SP*B070V17**16AHRI reference: 214212619 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3411887 → |
FEVB0036**+NAVA53601CKAHRI reference: 214277547 | 15.50 | 7.80 | 11400 | 2.08 | EPA 3415795 → |
FMA5X24**AL*AHRI reference: 214424037 | 15.50 | 7.80 | 10800 | 2.00 | EPA 3425320 → |
FM(C,U)5Z24**AL*AHRI reference: 215828897 | 15.50 | 8.00 | 11300 | 2.10 | EPA 3713311 → |
F55AA*B36L*AHRI reference: 216463787 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3847026 → |
FEVA0036**+NAVA53601CKAHRI reference: 217051513 | 15.50 | 8.00 | 11300 | 2.04 | EPA 4027334 → |
FM(C,U)5S36**AL*AHRI reference: 218452306 | 15.50 | 8.00 | 11200 | 2.10 | EPA 4624439 → |
FM(C,U)5S30**AL*AHRI reference: 218452274 | 15.50 | 8.00 | 11200 | 2.10 | EPA 4624471 → |
CAA**2517AM*+ furnace: 59SP6B060V14**12AHRI reference: 214130929 | 15.20 | 7.80 | 11500 | 2.08 | EPA 3399861 → |
CAA**2517AM*+ furnace: 59SC6A026M14**10AHRI reference: 214130846 | 15.20 | 7.80 | 11600 | 2.08 | EPA 3399965 → |
CAA**2517AM*+ furnace: 59SC6A060M14**12AHRI reference: 214130874 | 15.20 | 7.80 | 11600 | 2.08 | EPA 3399968 → |
CAA**3717AM*+ furnace: 59SC6A026M14**10AHRI reference: 214132897 | 15.20 | 7.80 | 11500 | 2.06 | EPA 3400022 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →