Carrier / AIR-SOURCE HEAT PUMP

GH5SAN524**AA*

15 SEER2 HP · source records, page 6

206 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5206 / 206
EER2 · BTU/Wh11.7–13206 / 206
HSPF2 · BTU/Wh7.8–8.5206 / 206
Cooling capacity · BTU/h22,200–24,400206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200206 / 206
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900206 / 206
COP at 5°F / −15°C1.96–2.26206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingSingle stage206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA3117XMA*+ furnace: 58S(B,C)*B070M17**16AHRI reference: 21420348215.507.80113001.98EPA 3408736
CVAVA3117XMA*+ furnace: 58TP*B070V17**16AHRI reference: 21420517515.507.80113001.98EPA 3408773
CVAVA3817XMA*+ furnace: 59TP6C060V17**16AHRI reference: 21420774015.507.80114001.98EPA 3408877
CVAVA3817XMA*+ furnace: GG96VTAB48060B**AHRI reference: 21420774115.507.80114001.98EPA 3408878
CAA**3717AM*+ furnace: 59TN6C060C17**14AHRI reference: 21420110215.507.80114002.08EPA 3408941
CAA**3717AM*+ furnace: 59TN6C080C17**14AHRI reference: 21420112915.507.80113002.08EPA 3408968
CAA**3721AM*+ furnace: 59SC2E080M17**16AHRI reference: 21421176715.507.80114002.14EPA 3409180
CAA**3721AM*+ furnace: 59SC2E080M21**20AHRI reference: 21421179715.507.80115002.16EPA 3409210
CVAVA3817XMA*+ furnace: 59SU5B060M17**16AHRI reference: 21421454415.507.80114001.98EPA 3409292
CAA**3721AM*+ furnace: 59SC2E100M21**20AHRI reference: 21421182515.507.80115002.16EPA 3409457
CAA**3721AM*+ furnace: 59SC2E100M21**22AHRI reference: 21421185515.507.80116002.16EPA 3409485
CAA**3721AM*+ furnace: 59SC6A100M21**20AHRI reference: 21421188015.507.80116002.14EPA 3409510
CAA**3721AM*+ furnace: 58S(B,C)*B090M17**14AHRI reference: 21421108015.507.80114002.14EPA 3409608
CAA**2517AM*+ furnace: 58S(B,C)*B070M17**12AHRI reference: 21421037415.507.80112002.12EPA 3409765
CAA**3721AM*+ furnace: 58S(B,C)*B090M21**20AHRI reference: 21421113815.507.80116002.14EPA 3409781
CAA**3721AM*+ furnace: 58S(B,C)*B110M21**20AHRI reference: 21421116815.507.80114002.14EPA 3409810
CAA**3721AM*+ furnace: 59SU5B100M21**22AHRI reference: 21421199515.507.80116002.16EPA 3409845
CAA**3721AM*+ furnace: 58SP*B110V21**22AHRI reference: 21421119815.507.80114002.14EPA 3409934
CVAMA3217XMA*+ furnace: 58TP*B070V17**16AHRI reference: 21421286115.507.80114001.98EPA 3409986
CVAMA3217XMA*+ furnace: 59SU5B060M17**16AHRI reference: 21421302515.507.80114001.98EPA 3410017