Carrier / AIR-SOURCE HEAT PUMP

GH5SAN524**AA*

15 SEER2 HP · source records, page 6

206 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5206 / 206
EER2 · BTU/Wh11.7–13206 / 206
HSPF2 · BTU/Wh7.8–8.5206 / 206
Cooling capacity · BTU/h22,200–24,400206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200206 / 206
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900206 / 206
COP at 5°F / −15°C1.96–2.26206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingSingle stage206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA3117XMA*+ furnace: 58S(B,C)*B070M17**16AHRI reference: 21420348215.507.80113001.98EPA 3408736 →
CVAVA3117XMA*+ furnace: 58TP*B070V17**16AHRI reference: 21420517515.507.80113001.98EPA 3408773 →
CVAVA3817XMA*+ furnace: 59TP6C060V17**16AHRI reference: 21420774015.507.80114001.98EPA 3408877 →
CVAVA3817XMA*+ furnace: GG96VTAB48060B**AHRI reference: 21420774115.507.80114001.98EPA 3408878 →
CAA**3717AM*+ furnace: 59TN6C060C17**14AHRI reference: 21420110215.507.80114002.08EPA 3408941 →
CAA**3717AM*+ furnace: 59TN6C080C17**14AHRI reference: 21420112915.507.80113002.08EPA 3408968 →
CAA**3721AM*+ furnace: 59SC2E080M17**16AHRI reference: 21421176715.507.80114002.14EPA 3409180 →
CAA**3721AM*+ furnace: 59SC2E080M21**20AHRI reference: 21421179715.507.80115002.16EPA 3409210 →
CVAVA3817XMA*+ furnace: 59SU5B060M17**16AHRI reference: 21421454415.507.80114001.98EPA 3409292 →
CAA**3721AM*+ furnace: 59SC2E100M21**20AHRI reference: 21421182515.507.80115002.16EPA 3409457 →
CAA**3721AM*+ furnace: 59SC2E100M21**22AHRI reference: 21421185515.507.80116002.16EPA 3409485 →
CAA**3721AM*+ furnace: 59SC6A100M21**20AHRI reference: 21421188015.507.80116002.14EPA 3409510 →
CAA**3721AM*+ furnace: 58S(B,C)*B090M17**14AHRI reference: 21421108015.507.80114002.14EPA 3409608 →
CAA**2517AM*+ furnace: 58S(B,C)*B070M17**12AHRI reference: 21421037415.507.80112002.12EPA 3409765 →
CAA**3721AM*+ furnace: 58S(B,C)*B090M21**20AHRI reference: 21421113815.507.80116002.14EPA 3409781 →
CAA**3721AM*+ furnace: 58S(B,C)*B110M21**20AHRI reference: 21421116815.507.80114002.14EPA 3409810 →
CAA**3721AM*+ furnace: 59SU5B100M21**22AHRI reference: 21421199515.507.80116002.16EPA 3409845 →
CAA**3721AM*+ furnace: 58SP*B110V21**22AHRI reference: 21421119815.507.80114002.14EPA 3409934 →
CVAMA3217XMA*+ furnace: 58TP*B070V17**16AHRI reference: 21421286115.507.80114001.98EPA 3409986 →
CVAMA3217XMA*+ furnace: 59SU5B060M17**16AHRI reference: 21421302515.507.80114001.98EPA 3410017 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →