Carrier / AIR-SOURCE HEAT PUMP

GH5SAN524**AA*

15 SEER2 HP · source records, page 8

206 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5206 / 206
EER2 · BTU/Wh11.7–13206 / 206
HSPF2 · BTU/Wh7.8–8.5206 / 206
Cooling capacity · BTU/h22,200–24,400206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200206 / 206
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900206 / 206
COP at 5°F / −15°C1.96–2.26206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingSingle stage206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: 59SC6A060M14**12AHRI reference: 21413292515.207.80116002.06EPA 3400049
CAA**3717AM*+ furnace: 59TP6C060V14**12AHRI reference: 21413310215.207.80115002.06EPA 3400088
CAA**3721AM*+ furnace: 58TN*B045C17**12AHRI reference: 21413313015.207.80117002.12EPA 3400143
CAA**3721AM*+ furnace: 59SU5B040M17**12AHRI reference: 21413321715.207.80118002.10EPA 3400209
CAA**3717AM*+ furnace: 58S(B,C)*B045M17**14AHRI reference: 21413262315.207.80114002.08EPA 3400227
CAA**3717AM*+ furnace: 58TN*B045C17**12AHRI reference: 21413267815.207.80114002.06EPA 3400255
CAA**2517AM*+ furnace: 59TP6C060V14**12AHRI reference: 21413101915.207.80115002.08EPA 3400281
FJ5AN*B30L*AHRI reference: 21417972015.207.80111002.06EPA 3404516
CAA**2517AM*+ furnace: 59SP6B060V17**16AHRI reference: 21419816615.207.80114002.10EPA 3404943
CAA**2517AM*+ furnace: 58SP*B090V17**16AHRI reference: 21419743415.207.80113002.12EPA 3404972
CAA**2517AM*+ furnace: 58S(B,C)*B045M14**12AHRI reference: 21419723615.207.80114002.10EPA 3405130
CAA**2517AM*+ furnace: 58S(B,C)*B045M17**14AHRI reference: 21419726815.207.80115002.10EPA 3405149
CAA**2517AM*+ furnace: 58S(B,C)*B070M17**16AHRI reference: 21419729615.207.80113002.12EPA 3405176
CAA**3617AM*+ furnace: 58S(B,C)*B090M17**14AHRI reference: 21419898515.207.80110002.02EPA 3405368
CAA**2517AM*+ furnace: 59SU5B060M17**16AHRI reference: 21419825515.207.80113002.12EPA 3405391
CAA**2517AM*+ furnace: 58SP*B070V17**16AHRI reference: 21419740915.207.80113002.10EPA 3405447
CAA**2517AM*+ furnace: 59TP6C060V17**16AHRI reference: 21419849315.207.80114002.10EPA 3405600
CAA**2517AM*+ furnace: GG96VTAB48060B**AHRI reference: 21419849415.207.80114002.10EPA 3405602
CAA**2517AM*+ furnace: 58TP*B070V17**16AHRI reference: 21419766115.207.80114002.10EPA 3405679
CAA**2517AM*+ furnace: 58TP*B090V17**16AHRI reference: 21419768915.207.80113002.12EPA 3405706