Carrier / AIR-SOURCE HEAT PUMP

GH5SAN524**AA*

15 SEER2 HP · source records, page 5

206 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5206 / 206
EER2 · BTU/Wh11.7–13206 / 206
HSPF2 · BTU/Wh7.8–8.5206 / 206
Cooling capacity · BTU/h22,200–24,400206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200206 / 206
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900206 / 206
COP at 5°F / −15°C1.96–2.26206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingSingle stage206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: 59SC2E080M17**16AHRI reference: 21420071815.507.80113002.10EPA 3407690
CVAMA3217XMA*+ furnace: 59TP6C080V17**16AHRI reference: 21420481815.507.80113001.98EPA 3407725
CVAMA3217XMA*+ furnace: GG96VTAB48080B**AHRI reference: 21420481915.507.80113001.98EPA 3407726
CAA**3721AM*+ furnace: 59SC6A100M21**22AHRI reference: 21420256515.507.80116002.14EPA 3407892
CVAVA3117XMA*+ furnace: 58S(B,C)*B070M17**16AHRI reference: 21420497515.507.80113001.98EPA 3408054
CAA**3717AM*+ furnace: 59SC6A080M17**16AHRI reference: 21420081615.507.80113002.08EPA 3408083
CVAMA3117XMA*+ furnace: 59SU5B060M17**16AHRI reference: 21420416215.507.80113001.98EPA 3408129
CAA**3717AM*+ furnace: 58SU*B040M17**12AHRI reference: 21420007115.507.80113002.10EPA 3408245
CAA**3721AM*+ furnace: 58SP*B090V21**20AHRI reference: 21420170615.507.80116002.14EPA 3408405
CAA**3721AM*+ furnace: 58SU*B100M21**20AHRI reference: 21420173115.507.80116002.14EPA 3408429
CVAVA3817XMA*+ furnace: 59SP6B060V17**16AHRI reference: 21420760115.507.80114001.98EPA 3408484
CVAVA3817XMA*+ furnace: 59SP6B080V17**16AHRI reference: 21420762615.507.80113001.98EPA 3408498
CAA**3717AM*+ furnace: 59SU5B060M17**16AHRI reference: 21420101615.507.80113002.08EPA 3408526
CAA**3721AM*+ furnace: 58TN*B070C21**20AHRI reference: 21420189615.507.80116002.14EPA 3408566
CAA**3721AM*+ furnace: 58TN*B090C17**16AHRI reference: 21420192315.507.80115002.14EPA 3408595
CAA**3721AM*+ furnace: 58TN*B070C17**16AHRI reference: 21420186915.507.80115002.14EPA 3408617
CAA**3717AM*+ furnace: 58TN*B070C14**12AHRI reference: 21420015715.507.80112002.08EPA 3408628
CAA**3717AM*+ furnace: 58TN*B070C17**16AHRI reference: 21420018415.507.80113002.08EPA 3408655
CAA**3717AM*+ furnace: 58TN*B090C17**16AHRI reference: 21420021115.507.80113002.08EPA 3408682
CAA**3721AM*+ furnace: 59SP6B100V21**20AHRI reference: 21420274815.507.80116002.14EPA 3408715

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →