GH5SAN524**AA*
15 SEER2 HP · source records, page 4
206 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 206 / 206 |
| EER2 · BTU/Wh | 11.7–13 | 206 / 206 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 206 / 206 |
| Cooling capacity · BTU/h | 22,200–24,400 | 206 / 206 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,600–24,000 | 206 / 206 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 206 / 206 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,800–11,900 | 206 / 206 |
| COP at 5°F / −15°C | 1.96–2.26 | 206 / 206 |
| Equipment / loop type | HP - Split System | 206 / 206 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 206 / 206 |
| Compressor staging | Single stage | 206 / 206 |
| Connected capability | No | 206 / 206 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3717AM*+ furnace: 59CU5B060C17**16AHRI reference: 214200427 | 15.50 | 7.80 | 11300 | 2.08 | EPA 3406748 → |
CAA**3721AM*+ furnace: 58TP*B090V21**20AHRI reference: 214202055 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406774 → |
CAA**3721AM*+ furnace: 59TN6C080C17**14AHRI reference: 214202971 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406803 → |
CAA**3721AM*+ furnace: 59TN6C060C17**14AHRI reference: 214202944 | 15.50 | 7.80 | 11600 | 2.12 | EPA 3406890 → |
CAA**3721AM*+ furnace: 58CU*A060C17**16AHRI reference: 214201315 | 15.50 | 7.80 | 11300 | 2.12 | EPA 3406913 → |
CAA**3721AM*+ furnace: 58CU*A100C21**20AHRI reference: 214201342 | 15.50 | 7.80 | 11500 | 2.12 | EPA 3406940 → |
CAA**3721AM*+ furnace: 59CU5B060C17**16AHRI reference: 214202137 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406956 → |
CAA**3721AM*+ furnace: 59CU5B080C21**20AHRI reference: 214202164 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406983 → |
CAA**3717AM*+ furnace: 59MN7C060C17**14AHRI reference: 214200508 | 15.50 | 7.80 | 11400 | 2.08 | EPA 3407084 → |
CVAMA3217XMA*+ furnace: 59SP6B060V17**16AHRI reference: 214204674 | 15.50 | 7.80 | 11400 | 1.98 | EPA 3407091 → |
CAA**3717AM*+ furnace: 59MN7C080C17**14AHRI reference: 214200535 | 15.50 | 7.80 | 11300 | 2.08 | EPA 3407128 → |
CAA**3721AM*+ furnace: 59MN7C060C17**14AHRI reference: 214202299 | 15.50 | 7.80 | 11700 | 2.12 | EPA 3407312 → |
CAA**3721AM*+ furnace: 59MN7C060C21**20AHRI reference: 214202326 | 15.50 | 7.80 | 11600 | 2.12 | EPA 3407317 → |
CAA**3721AM*+ furnace: 59MN7C080C17**14AHRI reference: 214202353 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3407344 → |
CAA**3721AM*+ furnace: 59SC2E060M17**14AHRI reference: 214202381 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3407371 → |
CVAVA3817XMA*+ furnace: 58S(B,C)*B045M17**14AHRI reference: 214207281 | 15.50 | 7.80 | 11500 | 1.98 | EPA 3407378 → |
CAA**3717AM*+ furnace: 58S(B,C)*B090M17**14AHRI reference: 214199819 | 15.50 | 7.80 | 11300 | 2.10 | EPA 3407383 → |
CVAMA3217XMA*+ furnace: 59TP6C060V17**16AHRI reference: 214204785 | 15.50 | 7.80 | 11400 | 1.98 | EPA 3407636 → |
CVAMA3217XMA*+ furnace: GG96VTAB48060B**AHRI reference: 214204786 | 15.50 | 7.80 | 11400 | 1.98 | EPA 3407638 → |
CAA**3717AM*+ furnace: 59SC2E060M17**14AHRI reference: 214200686 | 15.50 | 7.80 | 11300 | 2.08 | EPA 3407653 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →