Carrier / AIR-SOURCE HEAT PUMP

27TPA860A**30*

2-STAGE 18 SEER HP · source records, page 2

131 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA860A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 131 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5131 / 131
EER2 · BTU/Wh11.7–13131 / 131
HSPF2 · BTU/Wh7.8–8.5131 / 131
Cooling capacity · BTU/h54,000–58,000131 / 131
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500131 / 131
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500131 / 131
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800131 / 131
COP at 5°F / −15°C2.1–2.34131 / 131
Equipment / loop typeHP - Split System131 / 131
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)131 / 131
Compressor stagingTwo-stage131 / 131
Connected capabilityNo131 / 131

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**6121AM*+ furnace: 58TN*B110C21**20AHRI reference: 21562968616.508.00304002.25EPA 3951757 →
CAA**6121AM*+ furnace: 58TP*B110V21**22AHRI reference: 21562971616.508.00300002.30EPA 3951785 →
CAA**6124AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563043416.508.10298002.14EPA 3951939 →
CAA**6124AM*+ furnace: OVLAAB060154AHRI reference: 21563046516.508.00304002.25EPA 3951971 →
CAA**6124AM*+ furnace: 59SU5B100M21**22AHRI reference: 21563034216.508.00302002.25EPA 3952115 →
CAA**6124AM*+ furnace: 59TP7A100V21**22AHRI reference: 21571862716.508.00298002.30EPA 3997710 →
CAA**6121AM*+ furnace: 59TP7A100V21**22AHRI reference: 21571851016.508.00300002.30EPA 3997723 →
F55AA*D60L*AHRI reference: 21646429816.008.10302002.30EPA 3847210 →
CVAMA6124XMA*+ furnace: 58TP*B135V24**22AHRI reference: 21562666416.008.50314002.34EPA 3949863 →
CVAMA6124XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562691116.008.50316002.34EPA 3949869 →
CVAVA6021XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562698416.008.10304002.20EPA 3949883 →
CVAVA6021XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21562699716.008.10304002.20EPA 3949895 →
CVAVA6021XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21562701016.008.10306002.22EPA 3949908 →
CVAVA6021XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21562702916.008.10304002.22EPA 3949928 →
CVAVA6021XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21562704816.008.10304002.22EPA 3949946 →
CVAVA6021XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21562708116.008.10304002.22EPA 3949966 →
CVAVA6021XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562710916.008.10304002.20EPA 3949994 →
CVAVA6021XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21562712516.008.10304002.22EPA 3950082 →
CVAVA6021XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21562715716.008.10306002.20EPA 3950100 →
CVAVA6021XMA*+ furnace: 59SU5B100M21**22AHRI reference: 21562727716.008.10302002.22EPA 3950115 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →