27TPA860A**30*
2-STAGE 18 SEER HP
131 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27TPA860A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 131 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–17.5 | 131 / 131 |
| EER2 · BTU/Wh | 11.7–13 | 131 / 131 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 131 / 131 |
| Cooling capacity · BTU/h | 54,000–58,000 | 131 / 131 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–61,500 | 131 / 131 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 36,200–38,500 | 131 / 131 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,600–31,800 | 131 / 131 |
| COP at 5°F / −15°C | 2.1–2.34 | 131 / 131 |
| Equipment / loop type | HP - Split System | 131 / 131 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 131 / 131 |
| Compressor staging | Two-stage | 131 / 131 |
| Connected capability | No | 131 / 131 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FG5ANBD60L*AHRI reference: 215560730 | 17.50 | 8.10 | 30200 | 2.30 | EPA 3848819 → |
FT5ANBD60L*AHRI reference: 215560637 | 17.50 | 8.10 | 30200 | 2.30 | EPA 3848820 → |
FT5BD6021X*AHRI reference: 218695456 | 17.50 | 8.10 | 31400 | 2.34 | EPA 4683371 → |
CAA**6024AM*+ furnace: 58SU*B080M21**20AHRI reference: 215629085 | 16.50 | 8.00 | 29600 | 2.30 | EPA 3951001 → |
CAA**6121AM*+ furnace: 59SU5B100M21**22AHRI reference: 215629887 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951131 → |
CAA**6121AM*+ furnace: 59TP6C100V21**22AHRI reference: 215629965 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951177 → |
CAA**6124AM*+ furnace: 58CU*A080C21**20AHRI reference: 215629978 | 16.50 | 7.80 | 31400 | 2.22 | EPA 3951226 → |
CAA**6124AM*+ furnace: 58SP*B110V21**22AHRI reference: 215630019 | 16.50 | 8.10 | 29800 | 2.14 | EPA 3951382 → |
CAA**6124AM*+ furnace: 58SP*B135V24**22AHRI reference: 215630032 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951394 → |
CAA**6124AM*+ furnace: 58SU*B080M21**20AHRI reference: 215630045 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951408 → |
CAA**6124AM*+ furnace: 58SU*B100M21**20AHRI reference: 215630064 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951424 → |
CAA**6121AM*+ furnace: 58SP*B110V21**22AHRI reference: 215629574 | 16.50 | 8.10 | 30000 | 2.12 | EPA 3951529 → |
CAA**6121AM*+ furnace: 58SU*B080M21**20AHRI reference: 215629606 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951561 → |
CAA**6124AM*+ furnace: 58TN*B090C21**20AHRI reference: 215630097 | 16.50 | 8.10 | 30200 | 2.26 | EPA 3951606 → |
CAA**6124AM*+ furnace: 58TN*B110C21**20AHRI reference: 215630111 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951619 → |
CAA**6124AM*+ furnace: 58TN*B135C24**22AHRI reference: 215630125 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951633 → |
CAA**6124AM*+ furnace: 58TP*B110V21**22AHRI reference: 215630155 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951663 → |
CAA**6124AM*+ furnace: 58TP*B135V24**22AHRI reference: 215630173 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951679 → |
CAA**6124AM*+ furnace: 59CU5B100C21**22AHRI reference: 215630195 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951703 → |
CAA**6124AM*+ furnace: 59MN7C100C21**22AHRI reference: 215630237 | 16.50 | 8.10 | 30400 | 2.12 | EPA 3951731 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.