Carrier / AIR-SOURCE HEAT PUMP

27TPA860A**30*

2-STAGE 18 SEER HP · source records, page 3

131 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA860A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 131 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5131 / 131
EER2 · BTU/Wh11.7–13131 / 131
HSPF2 · BTU/Wh7.8–8.5131 / 131
Cooling capacity · BTU/h54,000–58,000131 / 131
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500131 / 131
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500131 / 131
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800131 / 131
COP at 5°F / −15°C2.1–2.34131 / 131
Equipment / loop typeHP - Split System131 / 131
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)131 / 131
Compressor stagingTwo-stage131 / 131
Connected capabilityNo131 / 131

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6021XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562735516.008.10302002.20EPA 3950129
CVAMA6021XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21562580616.008.10300002.24EPA 3950172
CVAMA6021XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21562581916.008.10300002.22EPA 3950184
CVAMA6021XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21562583816.008.10298002.24EPA 3950205
CVAMA6021XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21562585716.008.10304002.24EPA 3950223
CVAMA6021XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21562590416.008.10304002.22EPA 3950241
CVAMA6021XMA*+ furnace: 58TN*B110C21**20AHRI reference: 21562591816.008.10304002.24EPA 3950256
CVAMA6021XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21562594816.008.10300002.24EPA 3950271
CVAMA6021XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21562598016.008.10300002.24EPA 3950288
CVAMA6021XMA*+ furnace: 59SU5B100M21**20AHRI reference: 21562610016.008.10302002.22EPA 3950301
CVAMA6021XMA*+ furnace: 59SU5B100M21**22AHRI reference: 21562611916.008.10302002.22EPA 3950321
CVAMA6021XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562619716.008.10300002.24EPA 3950335
CVAMA6124XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562649716.008.50318002.32EPA 3950347
CVAMA6124XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21562653616.008.50316002.32EPA 3950364
CVAMA6124XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562663016.008.50318002.32EPA 3950379
CVAVA6121XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562774316.008.10310002.22EPA 3950529
CVAVA6121XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21562777516.008.10306002.22EPA 3950543
CVAVA6121XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21562779416.008.10310002.20EPA 3950578
CVAVA6121XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562785516.008.10310002.22EPA 3950653
CVAVA6121XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21562790316.008.10308002.20EPA 3950668

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →