Carrier / AIR-SOURCE HEAT PUMP

27TPA860A**30*

2-STAGE 18 SEER HP · source records, page 3

131 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA860A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 131 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5131 / 131
EER2 · BTU/Wh11.7–13131 / 131
HSPF2 · BTU/Wh7.8–8.5131 / 131
Cooling capacity · BTU/h54,000–58,000131 / 131
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500131 / 131
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500131 / 131
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800131 / 131
COP at 5°F / −15°C2.1–2.34131 / 131
Equipment / loop typeHP - Split System131 / 131
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)131 / 131
Compressor stagingTwo-stage131 / 131
Connected capabilityNo131 / 131

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6021XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562735516.008.10302002.20EPA 3950129 →
CVAMA6021XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21562580616.008.10300002.24EPA 3950172 →
CVAMA6021XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21562581916.008.10300002.22EPA 3950184 →
CVAMA6021XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21562583816.008.10298002.24EPA 3950205 →
CVAMA6021XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21562585716.008.10304002.24EPA 3950223 →
CVAMA6021XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21562590416.008.10304002.22EPA 3950241 →
CVAMA6021XMA*+ furnace: 58TN*B110C21**20AHRI reference: 21562591816.008.10304002.24EPA 3950256 →
CVAMA6021XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21562594816.008.10300002.24EPA 3950271 →
CVAMA6021XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21562598016.008.10300002.24EPA 3950288 →
CVAMA6021XMA*+ furnace: 59SU5B100M21**20AHRI reference: 21562610016.008.10302002.22EPA 3950301 →
CVAMA6021XMA*+ furnace: 59SU5B100M21**22AHRI reference: 21562611916.008.10302002.22EPA 3950321 →
CVAMA6021XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562619716.008.10300002.24EPA 3950335 →
CVAMA6124XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562649716.008.50318002.32EPA 3950347 →
CVAMA6124XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21562653616.008.50316002.32EPA 3950364 →
CVAMA6124XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562663016.008.50318002.32EPA 3950379 →
CVAVA6121XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562774316.008.10310002.22EPA 3950529 →
CVAVA6121XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21562777516.008.10306002.22EPA 3950543 →
CVAVA6121XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21562779416.008.10310002.20EPA 3950578 →
CVAVA6121XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562785516.008.10310002.22EPA 3950653 →
CVAVA6121XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21562790316.008.10308002.20EPA 3950668 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →