Carrier / AIR-SOURCE HEAT PUMP

27TPA836A**30*

2-STAGE 18 SEER HP · source records, page 2

285 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA836A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 285 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17285 / 285
EER2 · BTU/Wh11.7–13285 / 285
HSPF2 · BTU/Wh7.8–8.5285 / 285
Cooling capacity · BTU/h33,800–38,000285 / 285
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000285 / 285
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200285 / 285
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600285 / 285
COP at 5°F / −15°C1.78–2.48285 / 285
Equipment / loop typeHP - Split System285 / 285
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)285 / 285
Compressor stagingTwo-stage285 / 285
Connected capabilityNo285 / 285

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: 59SU5B100M21**22AHRI reference: 21563613616.008.10194002.26EPA 3955057 →
CAA**3721AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563636716.008.10192002.40EPA 3955132 →
CAA**4321AM*+ furnace: 58SP*B110V21**22AHRI reference: 21563771116.008.10192002.40EPA 3955491 →
CAA**4321AM*+ furnace: 58SU*B060M17**16AHRI reference: 21563775816.008.10193002.26EPA 3955524 →
CAA**4321AM*+ furnace: 58SU*B080M21**20AHRI reference: 21563778516.008.50191002.40EPA 3955542 →
CAA**4321AM*+ furnace: 59SU5B100M21**22AHRI reference: 21563839016.008.10191002.40EPA 3956020 →
CAA**4321AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563861816.008.10192002.40EPA 3956055 →
CAA**4821AM*+ furnace: 58SU*B080M21**20AHRI reference: 21563887816.008.10190002.40EPA 3956118 →
CAA**4821AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563974416.008.10191002.26EPA 3956440 →
CAA**3721AM*+ furnace: 58CU*B080C21**20AHRI reference: 21572135616.008.00192002.28EPA 3982083 →
CAA**4321AM*+ furnace: 58CU*B080C21**20AHRI reference: 21572151716.008.00192002.40EPA 3982128 →
CAA**4821AM*+ furnace: 59TP7A100V21**22AHRI reference: 21572159116.008.00191002.26EPA 3982196 →
CVAMA4921XMA*+ furnace: 59TP7A100V21**20AHRI reference: 21571629416.008.00179001.90EPA 3997638 →
CVAVA3817XMA*+ furnace: 58CU*B060C17**16AHRI reference: 21571669616.008.00175001.82EPA 3997656 →
CVAVA3817XMA*+ furnace: 58CU*B040C17**12AHRI reference: 21571668216.008.00176001.82EPA 3997670 →
CAA**3721AM*+ furnace: 59TP7A100V21**22AHRI reference: 21571484616.008.50192002.40EPA 3997697 →
FT5BD3617X*AHRI reference: 21869538816.008.10183002.20EPA 4683439 →
CAA**4321AM*+ furnace: 59TN6C080C21**20AHRI reference: 21563845815.508.00193002.26EPA 3719669 →
CVAMA4821XMA*+ furnace: 58CU*A080C21**20AHRI reference: 21561944715.507.80176001.78EPA 3946239 →
CVAMA4821XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21561950015.507.80177001.78EPA 3946283 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.