Carrier / AIR-SOURCE HEAT PUMP

27TPA836A**30*

2-STAGE 18 SEER HP · source records, page 3

285 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA836A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 285 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17285 / 285
EER2 · BTU/Wh11.7–13285 / 285
HSPF2 · BTU/Wh7.8–8.5285 / 285
Cooling capacity · BTU/h33,800–38,000285 / 285
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000285 / 285
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200285 / 285
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600285 / 285
COP at 5°F / −15°C1.78–2.48285 / 285
Equipment / loop typeHP - Split System285 / 285
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)285 / 285
Compressor stagingTwo-stage285 / 285
Connected capabilityNo285 / 285

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA4821XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21561951315.507.80177001.78EPA 3946305
CVAMA4821XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21561966815.507.80178001.78EPA 3946362
CVAMA4821XMA*+ furnace: 59TN6C080C21**20AHRI reference: 21561976715.507.80178001.78EPA 3946428
CVAMA4821XMA*+ furnace: 59TP6C100V21**20AHRI reference: 21561983715.507.80178001.78EPA 3946456
CVAMA4821XMA*+ furnace: GG96VTAB60100C**AHRI reference: 21561983815.507.80178001.78EPA 3946462
CVAVA3817XMA*+ furnace: 58SP*B070V17**16AHRI reference: 21562129515.507.80177001.78EPA 3946488
CVAMA4821XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21561985715.507.80176001.80EPA 3946513
CVAMA4921XMA*+ furnace: 58SP*B090V17**16AHRI reference: 21561987015.507.80180001.78EPA 3946524
CVAMA4921XMA*+ furnace: 58TN*B090C17**16AHRI reference: 21561991515.507.80180001.78EPA 3946570
CVAMA4921XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21561992915.507.80178001.82EPA 3946586
CVAMA4921XMA*+ furnace: 58TP*B090V17**16AHRI reference: 21561995915.507.80180001.78EPA 3946614
CVAVA3721XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562091415.507.80177001.80EPA 3946688
CVAVA3721XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21562092715.507.80177001.78EPA 3946700
CVAVA3721XMA*+ furnace: 59TN6C080C21**20AHRI reference: 21562115115.507.80178001.78EPA 3946717
CVAVA3721XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562124115.507.80176001.80EPA 3946769
CVAVA3817XMA*+ furnace: 58CU*A040C17**12AHRI reference: 21562125415.507.80178001.80EPA 3946781
CVAVA3721XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21562094015.507.80177001.78EPA 3946787
CVAVA3721XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562102215.507.80177001.80EPA 3946806
CVAVA3721XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21562105215.507.80178001.78EPA 3946822
CVAVA3817XMA*+ furnace: 58TN*B070C17**16AHRI reference: 21562138715.507.80177001.78EPA 3946911