27TPA836A**30*
2-STAGE 18 SEER HP
285 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27TPA836A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 285 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 285 / 285 |
| EER2 · BTU/Wh | 11.7–13 | 285 / 285 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 285 / 285 |
| Cooling capacity · BTU/h | 33,800–38,000 | 285 / 285 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,200–39,000 | 285 / 285 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 23,000–24,200 | 285 / 285 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,500–19,600 | 285 / 285 |
| COP at 5°F / −15°C | 1.78–2.48 | 285 / 285 |
| Equipment / loop type | HP - Split System | 285 / 285 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 285 / 285 |
| Compressor staging | Two-stage | 285 / 285 |
| Connected capability | No | 285 / 285 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FT5ANBD60L*AHRI reference: 215628934 | 17.00 | 8.50 | 18600 | 2.48 | EPA 3950868 → |
FG5ANBD60L*AHRI reference: 215628935 | 17.00 | 8.50 | 18600 | 2.48 | EPA 3950872 → |
FT5AN(B,X)C48L*AHRI reference: 215628880 | 16.50 | 8.10 | 18700 | 2.30 | EPA 3950420 → |
FG5ANXC48L*AHRI reference: 215628881 | 16.50 | 8.10 | 18700 | 2.30 | EPA 3950422 → |
FT5BD4821X*AHRI reference: 218695405 | 16.50 | 8.10 | 18400 | 2.24 | EPA 4683422 → |
CVAMA4821XMA*+ furnace: 58SU*B080M21**20AHRI reference: 215619532 | 16.00 | 8.00 | 17500 | 1.90 | EPA 3946326 → |
CVAMA4921XMA*+ furnace: 58SP*B090V21**20AHRI reference: 215619883 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946540 → |
CVAMA4921XMA*+ furnace: 58SU*B080M21**20AHRI reference: 215619896 | 16.00 | 8.00 | 17700 | 1.95 | EPA 3946551 → |
CVAMA4921XMA*+ furnace: 58TP*B090V21**20AHRI reference: 215619969 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946625 → |
CVAMA4921XMA*+ furnace: 59CU5B100C21**22AHRI reference: 215619999 | 16.00 | 8.00 | 17900 | 1.95 | EPA 3946643 → |
CVAMA4921XMA*+ furnace: 59TN6C080C21**20AHRI reference: 215620040 | 16.00 | 7.80 | 17900 | 1.80 | EPA 3946656 → |
CVAMA4921XMA*+ furnace: 59TP6C100V21**20AHRI reference: 215620074 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946667 → |
CVAMA4921XMA*+ furnace: GG96VTAB60100C**AHRI reference: 215620075 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946669 → |
CVAVA3817XMA*+ furnace: 58SP*B090V17**16AHRI reference: 215621308 | 16.00 | 8.00 | 17600 | 1.90 | EPA 3946860 → |
CVAVA3817XMA*+ furnace: 58SU*B040M17**12AHRI reference: 215621321 | 16.00 | 8.00 | 17600 | 1.85 | EPA 3946873 → |
CVAVA3817XMA*+ furnace: 58SU*B060M17**16AHRI reference: 215621340 | 16.00 | 8.00 | 17600 | 1.90 | EPA 3946892 → |
CVAVA3817XMA*+ furnace: 58TN*B090C17**16AHRI reference: 215621401 | 16.00 | 7.80 | 17600 | 1.80 | EPA 3946924 → |
CVAVA3817XMA*+ furnace: 58TP*B090V17**16AHRI reference: 215621441 | 16.00 | 8.00 | 17600 | 1.90 | EPA 3946968 → |
CAA**3721AM*+ furnace: 58SP*B110V21**22AHRI reference: 215635682 | 16.00 | 8.10 | 19400 | 2.24 | EPA 3954578 → |
CAA**3721AM*+ furnace: 58SU*B060M17**16AHRI reference: 215635712 | 16.00 | 8.10 | 19300 | 2.26 | EPA 3954616 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →