Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 4

114 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.3BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 114 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6114 / 114
EER2 · BTU/Wh12.5–13114 / 114
HSPF2 · BTU/Wh8–8.3114 / 114
Cooling capacity · BTU/h46,000–48,000114 / 114
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000114 / 114
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,600114 / 114
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600114 / 114
COP at 5°F / −15°C2.16–2.38114 / 114
Equipment / loop typeHP - Split System114 / 114
Refrigerant / source-reported GWPR-410A (GWP:2088)114 / 114
Compressor stagingSingle stage114 / 114
Connected capabilityNo114 / 114

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X49C+TDR+ furnace: 96G1UH110CE20AHRI reference: 21331593215.208.10254002.26EPA 2841065
EAC4X60C+TDR+ furnace: 92G1UH090CE16AHRI reference: 21331595215.208.10252002.34EPA 2841073
EA(C;U)1P49C+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21331587515.208.10254002.22EPA 2841076
EAC4X48C+TDR+ furnace: 92G1UH110CE16AHRI reference: 21331591615.208.10244002.18EPA 2841087
EAC4X48C+TDR+ furnace: 96G1UH110CE20AHRI reference: 21331591915.208.10242002.18EPA 2841091
EA(C;U)1P60C+TDR+TXV+ furnace: 92G1UH090CE16AHRI reference: 21331589815.208.10252002.34EPA 2841092
EAH1P48C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21331597115.208.00244002.18EPA 2841099
EAH1P48C*+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21331597715.208.00248002.18EPA 2841100
BCE5V48M*4XAHRI reference: 21331585315.208.30242002.28EPA 2841101
EA(C;U)1P48B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21331585515.208.10242002.18EPA 2841102
EA(C;U)1P49C+TDR+TXV+ furnace: 96G1UH090CE16AHRI reference: 21331587715.208.10254002.24EPA 2841104
EA(C;U)1P49C+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21331587815.208.10254002.26EPA 2841105
EAC4X49C+TDR+ furnace: 80G1UH110CE20AHRI reference: 21331592715.208.10256002.26EPA 2841111
EAC4X49C+TDR+ furnace: 92G1UH110CE16AHRI reference: 21331592915.208.10254002.22EPA 2841112
EAH1P51C*+TDR+TXV+ furnace: 92G1UH110CE20AHRI reference: 21331598715.208.30256002.28EPA 2841178
EAC4X50/60C+TDR+ furnace: 80G1UH090CE20AHRI reference: 21331593815.208.00242002.18EPA 2841179
7EH51CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21470915115.208.30256002.30EPA 3491612
7EH51CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21470915315.208.30256002.30EPA 3491700
7EC49CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21470919815.208.10254002.24EPA 3491712
7EC48BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21470917115.208.10242002.18EPA 3491733

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →