Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 3

114 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.3BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 114 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6114 / 114
EER2 · BTU/Wh12.5–13114 / 114
HSPF2 · BTU/Wh8–8.3114 / 114
Cooling capacity · BTU/h46,000–48,000114 / 114
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000114 / 114
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,600114 / 114
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600114 / 114
COP at 5°F / −15°C2.16–2.38114 / 114
Equipment / loop typeHP - Split System114 / 114
Refrigerant / source-reported GWPR-410A (GWP:2088)114 / 114
Compressor stagingSingle stage114 / 114
Connected capabilityNo114 / 114

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC60CX-0*+TDR+ furnace: 96G1UH110CE20AHRI reference: 21470924715.408.10252002.34EPA 3494557
7EC60CX-0*+TDR+ furnace: 96G1UH090CE16AHRI reference: 21470924615.408.10254002.36EPA 3494558
7EC60CX-0*+TDR+ furnace: 80G2UH110CV20AHRI reference: 21470924815.408.30254002.32EPA 3494559
7EH51CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21470914515.408.30254002.28EPA 3494597
7EC48CX-0*+TDR+ furnace: 92G1UH110CE20AHRI reference: 21470918915.408.10244002.18EPA 3494624
7EC49CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21470919515.408.10254002.26EPA 3494648
7EC49CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21470919615.408.10254002.26EPA 3494649
7EC49CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21470919715.408.10254002.26EPA 3494650
7EH51CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21470915415.408.30256002.32EPA 3494749
7EC48CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21470918415.408.10244002.22EPA 3494869
7EH51CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21470914415.408.30254002.28EPA 3494872
EAH1P60D*+TDR+TXV+ furnace: 96G1UH135DE20AHRI reference: 21331599415.208.10246002.20EPA 2840908
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21331588415.208.00242002.18EPA 2841040
EAH1P51C*+TDR+TXV+ furnace: 80G1UH110CE20AHRI reference: 21331598415.208.30256002.30EPA 2841048
EAH1P51C*+TDR+TXV+ furnace: 92G1UH090CE16AHRI reference: 21331598515.208.30256002.30EPA 2841049
EA(C;U)1P49C+TDR+TXV+ furnace: 80G1UH110CE20AHRI reference: 21331587315.208.10256002.26EPA 2841053
EAC4X48B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21331590915.208.10242002.18EPA 2841056
EA(C;U)1P48C+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21331586215.208.10244002.18EPA 2841058
EA(C;U)1P48C+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21331586515.208.10242002.18EPA 2841060
EAC4X49C+TDR+ furnace: 96G1UH090CE16AHRI reference: 21331593115.208.10254002.24EPA 2841064

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →