Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 12

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8249 / 249
EER2 · BTU/Wh12.2–14249 / 249
HSPF2 · BTU/Wh7.8–8.7249 / 249
Cooling capacity · BTU/h35,000–36,000249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800249 / 249
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200249 / 249
COP at 5°F / −15°C2.06–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X36B+TDR+ furnace: 92G1UH030BE12AHRI reference: 21331562115.607.80174002.12EPA 2840846 →
EAH1P48B*+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21331567415.607.80175002.20EPA 2840873 →
BCE5C42M*4XAHRI reference: 21331557515.608.10176002.16EPA 2841168 →
7ED30/36CX-0*+TDR+ furnace: 97G2DF110CE20AHRI reference: 21470888615.608.00189002.12EPA 3491735 →
7EH48BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470884215.607.80174002.18EPA 3494355 →
7EH48BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470884315.608.00178002.20EPA 3494358 →
7EH42BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470879915.608.10188002.18EPA 3494403 →
7EH42BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470880015.608.10189002.26EPA 3494404 →
7EH42BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21470880515.608.00187002.20EPA 3494409 →
7EH48BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21470883515.607.80175002.20EPA 3494464 →
7EC36BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21470892715.607.80174002.12EPA 3494745 →
7ED30/36BX-0*+TDR+ furnace: 80G2DF090BE16AHRI reference: 21470887615.608.00187002.12EPA 3543615 →
7EH48BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21470885215.607.80174002.18EPA 3543718 →
7EH48BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21470885115.607.80174002.18EPA 3543719 →
7EH48BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 21470884915.607.80175002.20EPA 3543722 →
7AH1AC42PX-0*AHRI reference: 21486538815.608.10176002.16EPA 3553769 →
7AH1AE36PX-0*AHRI reference: 21486542215.507.80171002.16EPA 3553789 →
EAD4X-30/36B+TDR+ furnace: 92G1DF045BE12AHRI reference: 21331564715.407.90187002.12EPA 2840856 →
EAD4X-30/36B+TDR+ furnace: 92G1DF070BE12AHRI reference: 21331564815.407.90186002.08EPA 2840857 →
EAH1P48B*+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21331567315.407.80176002.18EPA 2841152 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →