Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 11

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8249 / 249
EER2 · BTU/Wh12.2–14249 / 249
HSPF2 · BTU/Wh7.8–8.7249 / 249
Cooling capacity · BTU/h35,000–36,000249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800249 / 249
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200249 / 249
COP at 5°F / −15°C2.06–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC50/60CX-0*+TDR+ furnace: 95G1UH080CE16XAHRI reference: 21470895615.807.80172002.10EPA 3494614
7EC50/60CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21470896315.807.80176002.12EPA 3494663
7EC36BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21470891415.807.80170002.12EPA 3494714
7EC36BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470892115.807.80172002.06EPA 3494740
7EC36BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470892215.807.80174002.12EPA 3494741
7EC36BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 21470892815.807.80170002.08EPA 3494747
7EC50/60CX-0*+TDR+ furnace: 80G2UH110CV20AHRI reference: 21470897515.807.80174002.10EPA 3494853
7ED30/36CX-0*+TDR+ furnace: 96G1DF110CE20AHRI reference: 21470889115.808.10189002.12EPA 3543637
7ED30/36CX-0*+TDR+ furnace: 92G1DF090CE16AHRI reference: 21470888915.808.00187002.14EPA 3543638
7ED48CX-0*+TDR+ furnace: 97G2DF110CV20AHRI reference: 21470889615.808.60190002.26EPA 3543645
7ED48CX-0*+TDR+ furnace: 97G2DF090CV20AHRI reference: 21470889415.808.60190002.24EPA 3543658
7EH42BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21470879715.808.10185002.24EPA 3543669
7EH42BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21470879315.808.00183002.20EPA 3543674
7EH42BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21470879215.808.00183002.20EPA 3543675
7EH48BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21470885315.808.00176002.22EPA 3543711
7AH1AV36PX-0*AHRI reference: 21486536115.808.10174002.20EPA 3553716
7AH2AE36PX-0*AHRI reference: 21486536315.808.10185002.28EPA 3553718
EAH1P48B*+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21331567615.607.80174002.18EPA 2840675
EAH1P48B*+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21331567715.607.80174002.18EPA 2840676
EA(C;U)1P36B+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21331558815.607.80174002.12EPA 2840836

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →