Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 3

199 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17199 / 199
EER2 · BTU/Wh12.5–14199 / 199
HSPF2 · BTU/Wh7.8–8.2199 / 199
Cooling capacity · BTU/h22,400–24,000199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500199 / 199
COP at 5°F / −15°C2–2.16199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-410A (GWP:2088)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470865116.407.80104002.06EPA 3494387
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470865216.407.80104002.06EPA 3494388
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21470865316.407.80104002.06EPA 3494389
7EH24AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21470854516.407.80104002.06EPA 3494421
7EH24AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21470854616.407.80104002.06EPA 3494422
7EH30BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21470857416.407.80102002.04EPA 3494449
7EH30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21470857716.407.80102002.02EPA 3494454
7EC30AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21470863316.407.80102002.06EPA 3494510
7EC24BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21470861316.407.80104002.04EPA 3494522
7EH30BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21470858016.407.80104002.04EPA 3494569
7EC24AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21470860016.407.80102002.04EPA 3494575
7EH30BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21470856016.407.80106002.02EPA 3543602
7EH30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21470855816.408.10106002.12EPA 3543603
7EC30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21470864016.407.80104002.04EPA 3543667
7EC24BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21470862216.407.80104002.08EPA 3543681
7EC24BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21470862116.407.80104002.08EPA 3543689
7EC24BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21470862016.407.80104002.04EPA 3543690
7EC24BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470861916.407.80104002.04EPA 3543691
7EC24BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470861816.407.80104002.04EPA 3543692
7EC24BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470861416.407.80104002.04EPA 3543696

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.