Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 2

199 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17199 / 199
EER2 · BTU/Wh12.5–14199 / 199
HSPF2 · BTU/Wh7.8–8.2199 / 199
Cooling capacity · BTU/h22,400–24,000199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500199 / 199
COP at 5°F / −15°C2–2.16199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-410A (GWP:2088)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P30B*+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21331543916.407.80102002.04EPA 2840691
EAH1P30B*+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21331544216.407.80102002.02EPA 2840694
EAD4X-30/36C+TDR+ furnace: 96G1DF090CE16AHRI reference: 21331542016.408.20112002.10EPA 2840737
EAC4X24B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21331537516.407.80104002.04EPA 2840764
EAC4X24B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21331537716.407.80104002.08EPA 2840765
EA(C;U)1P24B+TDR+TXV+ furnace: 80G1UH070BE12AHRI reference: 21331533516.407.80104002.04EPA 2840770
EA(C;U)1P24B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21331533716.407.80104002.08EPA 2840831
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH070BE12AHRI reference: 21331535516.407.80104002.06EPA 2840956
EAH1P24A*+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21331542716.407.80104002.06EPA 2840972
EAH1P24A*+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21331542816.407.80104002.06EPA 2840973
EAH1P30A*+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21331543116.408.00102002.08EPA 2840974
EAH1P30A*+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21331543316.408.00104002.14EPA 2840977
EAH1P30A*+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21331543416.408.00104002.14EPA 2840978
7ED30/36CX-0*+TDR+ furnace: 96G1DF090CE16AHRI reference: 21470859516.408.20112002.10EPA 3494329
7EH30AX-0*+TDR+ furnace: 80G1UH045AE12AHRI reference: 21470855416.408.00102002.08EPA 3494348
7EH30AX-0*+TDR+ furnace: 80G1UH045AE12LAHRI reference: 21470855516.408.00102002.08EPA 3494349
7EH30AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21470855616.408.00104002.14EPA 3494350
7EH30AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21470855716.408.00104002.14EPA 3494351
7EC30BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470864716.408.00104002.06EPA 3494382
7EC30BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21470864616.408.00104002.06EPA 3494383