BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L24P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 5

143 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–24,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17143 / 143
EER2 · BTU/Wh12.5–14143 / 143
HSPF2 · BTU/Wh7.8–8.2143 / 143
Cooling capacity · BTU/h22,600–24,000143 / 143
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600143 / 143
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700143 / 143
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500143 / 143
COP at 5°F / −15°C2–2.14143 / 143
Equipment / loop typeHP - Split System143 / 143
Refrigerant / source-reported GWPR-410A (GWP:2088)143 / 143
Compressor stagingSingle stage143 / 143
Connected capabilityNo143 / 143

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC4X24B+TDR+ furnace: BG802UH090BV16AHRI reference: 21044123016.007.80104002.04EPA 2472247
BC4X30B+TDR+ furnace: BG802UH090BE12AHRI reference: 21044123716.007.80106002.00EPA 2472250
BC4X24B+TDR+ furnace: BG921UH070BE12AHRI reference: 21044122716.007.80106002.06EPA 2472337
BC4X24B+TDR+ furnace: BG802UH090BE12AHRI reference: 21044122116.007.80106002.02EPA 2472340
BC1P30B+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21044121016.007.80104002.00EPA 2472347
BC1P30A+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21032550916.007.80104002.00EPA 2472388
BC1P24A+TDR+TXV+ furnace: BG921UH070BE12AHRI reference: 21032547316.007.80106002.06EPA 2472390
BC1P24A+TDR+TXV+ furnace: BG802UH070AE12AHRI reference: 21032546516.007.80106002.02EPA 2472398
BC1P30B+TDR+TXV+ furnace: BG802UH090BE12AHRI reference: 21044120116.007.80106002.00EPA 2472460
BC1P24A+TDR+TXV+ furnace: BG802UH090BE12AHRI reference: 21032547816.007.80106002.02EPA 2472506
BC1P24A+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21032548016.007.80104002.04EPA 2472514
BD4X-30/36B+TDR+ furnace: BG802DF070AE12AHRI reference: 21326550616.008.20112002.08EPA 2648765
BC1P24B+TDR+TXV+ furnace: BG802UH090BE12AHRI reference: 21044119016.007.80106002.02EPA 2837129
BH1P30B*+TDR+TXV+ furnace: BG961UH045BE12AHRI reference: 21173530116.007.80108002.04EPA 2837364
BH1P30B*+TDR+TXV+ furnace: BG961UH070BE12AHRI reference: 21173531816.007.80108002.04EPA 2837377
BC724CAT-0*+TDR+ furnace: BG802UH070AE12AHRI reference: 21471335016.007.80106002.02EPA 3486807
BC724HAT-0*+TDR+ furnace: BG802UH070AE12AHRI reference: 21471332316.007.80105002.04EPA 3486876
BC730HAT-0*+TDR+ furnace: BG802UH070AE12AHRI reference: 21471332816.008.10108002.12EPA 3486887
BC730CBT-0*+TDR+ furnace: BG802UH090BE12AHRI reference: 21471337016.007.80106002.00EPA 3486956
BC724CBT-0*+TDR+ furnace: BG921UH070BE12AHRI reference: 21471336016.007.80106002.06EPA 3487007

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →