BHP17L24P-**A
BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 4
143 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for BHP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.4–17 | 143 / 143 |
| EER2 · BTU/Wh | 12.5–14 | 143 / 143 |
| HSPF2 · BTU/Wh | 7.8–8.2 | 143 / 143 |
| Cooling capacity · BTU/h | 22,600–24,000 | 143 / 143 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,000–22,600 | 143 / 143 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 13,400–14,700 | 143 / 143 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,200–11,500 | 143 / 143 |
| COP at 5°F / −15°C | 2–2.14 | 143 / 143 |
| Equipment / loop type | HP - Split System | 143 / 143 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 143 / 143 |
| Compressor staging | Single stage | 143 / 143 |
| Connected capability | No | 143 / 143 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
BC1P24A+TDR+TXV+ furnace: BG802UH070AV12AHRI reference: 210325467 | 16.20 | 7.80 | 10400 | 2.04 | EPA 2472511 → |
BD4X-30/36B+TDR+ furnace: BG80G1DF090BE16AHRI reference: 213265507 | 16.20 | 8.20 | 11200 | 2.12 | EPA 2648833 → |
BH1P30B*+TDR+TXV+ furnace: BG921UH045BE12AHRI reference: 211735257 | 16.20 | 7.80 | 10600 | 2.06 | EPA 2837386 → |
BC724CAT-0*+TDR+ furnace: BG801UH070AE12AHRI reference: 214713352 | 16.20 | 7.80 | 10400 | 2.02 | EPA 3486741 → |
BC724CAT-0*+TDR+ furnace: BG802UH070AV12AHRI reference: 214713353 | 16.20 | 7.80 | 10400 | 2.04 | EPA 3486758 → |
BC724HAT-0*+TDR+ furnace: BG801UH045AE12AHRI reference: 214713324 | 16.20 | 7.80 | 10200 | 2.04 | EPA 3486880 → |
BC724HAT-0*+TDR+ furnace: BG802UH070AV12AHRI reference: 214713326 | 16.20 | 7.80 | 10600 | 2.08 | EPA 3486884 → |
BC730CBT-0*+TDR+ furnace: BG921UH070BE12AHRI reference: 214713375 | 16.20 | 7.80 | 10600 | 2.04 | EPA 3486964 → |
BC730HBT-0*+TDR+ furnace: BG921UH045BE12AHRI reference: 214713337 | 16.20 | 7.80 | 10600 | 2.06 | EPA 3487017 → |
BC730CAT-0*+TDR+ furnace: BG801UH070AE12AHRI reference: 214713367 | 16.20 | 7.80 | 10400 | 2.04 | EPA 3487096 → |
BC730/36DBT-0*+TDR+ furnace: BG80G1DF090BE16AHRI reference: 214713343 | 16.20 | 8.20 | 11200 | 2.12 | EPA 3487133 → |
BC730CAT-0*+TDR+ furnace: BG801UH045AE12AHRI reference: 214713366 | 16.20 | 7.80 | 10200 | 2.02 | EPA 3491887 → |
BE5V30MA4XAHRI reference: 211855656 | 16.00 | 8.10 | 10400 | 2.06 | EPA 2471028 → |
BC1P24B+TDR+TXV+ furnace: BG921UH070BE12AHRI reference: 210441196 | 16.00 | 7.80 | 10600 | 2.06 | EPA 2471182 → |
BC1P24B+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 210441199 | 16.00 | 7.80 | 10400 | 2.04 | EPA 2471197 → |
BC4X24A+TDR+ furnace: BG802UH070AE12AHRI reference: 210441216 | 16.00 | 7.80 | 10600 | 2.02 | EPA 2471209 → |
BH1P30A*+TDR+TXV+ furnace: BG802UH070AE12AHRI reference: 211735051 | 16.00 | 8.10 | 10800 | 2.12 | EPA 2471714 → |
BH1P24A*+TDR+TXV+ furnace: BG802UH070AE12AHRI reference: 211734944 | 16.00 | 7.80 | 10500 | 2.04 | EPA 2471938 → |
BC4X30B+TDR+ furnace: BG802UH090BV16AHRI reference: 210441246 | 16.00 | 7.80 | 10400 | 2.00 | EPA 2472019 → |
BC1P30A+TDR+TXV+ furnace: BG802UH090BE12AHRI reference: 210325507 | 16.00 | 7.80 | 10600 | 2.00 | EPA 2472177 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →