BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L24P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 6

143 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–24,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17143 / 143
EER2 · BTU/Wh12.5–14143 / 143
HSPF2 · BTU/Wh7.8–8.2143 / 143
Cooling capacity · BTU/h22,600–24,000143 / 143
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600143 / 143
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700143 / 143
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500143 / 143
COP at 5°F / −15°C2–2.14143 / 143
Equipment / loop typeHP - Split System143 / 143
Refrigerant / source-reported GWPR-410A (GWP:2088)143 / 143
Compressor stagingSingle stage143 / 143
Connected capabilityNo143 / 143

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC724CBT-0*+TDR+ furnace: BG802UH090BV16AHRI reference: 21471336316.007.80104002.04EPA 3487090
BC730CBT-0*+TDR+ furnace: BG802UH090BV16AHRI reference: 21471337816.007.80104002.00EPA 3487099
BC730HBT-0*+TDR+ furnace: BG961UH045BE12AHRI reference: 21471333916.007.80108002.04EPA 3487128
BC730HBT-0*+TDR+ furnace: BG961UH070BE12AHRI reference: 21471334016.007.80108002.04EPA 3487131
BC730/36DBT-0*+TDR+ furnace: BG802DF070AE12AHRI reference: 21471334216.008.20112002.08EPA 3487135
BC724CBT-0*+TDR+ furnace: BG802UH090BE12AHRI reference: 21471335516.007.80106002.02EPA 3487215
BAH7E24PT-0*AHRI reference: 21486616816.007.80104002.08EPA 3553930
BAH7E30PT-0*AHRI reference: 21486617016.008.10108002.06EPA 3553932
BAH7V30PT-0*AHRI reference: 21486615716.008.10104002.06EPA 3553951
BC1P24B+TDR+TXV+ furnace: BG921UH045BE12AHRI reference: 21044119515.807.80106002.00EPA 2471234
BC4X30A+TDR+ furnace: BG802UH070AE12AHRI reference: 21044123215.807.80106002.04EPA 2472138
BC4X24B+TDR+ furnace: BG921UH045BE12AHRI reference: 21044122615.807.80106002.00EPA 2472157
BC4X30B+TDR+ furnace: BG921UH045BE12AHRI reference: 21044124215.807.80106002.00EPA 2472242
BC1P24A+TDR+TXV+ furnace: BG921UH045BE12AHRI reference: 21032547115.807.80106002.00EPA 2472276
BC1P30A+TDR+TXV+ furnace: BG802UH070AE12AHRI reference: 21032549415.807.80106002.04EPA 2472387
BC1P30A+TDR+TXV+ furnace: BG921UH045BE12AHRI reference: 21032550015.807.80106002.00EPA 2472396
BE5V24MA4XAHRI reference: 21032545715.808.00108002.12EPA 2472512
BC1P30B+TDR+TXV+ furnace: BG921UH045BE12AHRI reference: 21044120615.807.80106002.00EPA 2837230
BC730CBT-0*+TDR+ furnace: BG921UH045BE12AHRI reference: 21471337415.807.80106002.00EPA 3486962
BC724CBT-0*+TDR+ furnace: BG921UH045BE12AHRI reference: 21471335915.807.80106002.00EPA 3487006

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →