American Standard / AIR-SOURCE HEAT PUMP

5A6H6042A1

Silver 16 · source records, page 12

248 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,600–41,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 248 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5248 / 248
EER2 · BTU/Wh11.7–12248 / 248
HSPF2 · BTU/Wh7.8–8.5248 / 248
Cooling capacity · BTU/h37,600–41,500248 / 248
Heating capacity at 47°F / 8.3°C · BTU/h37,600–40,500248 / 248
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,200248 / 248
Heating capacity at 5°F / −15°C · BTU/h18,700–19,900248 / 248
COP at 5°F / −15°C2.12–2.32248 / 248
Equipment / loop typeHP - Split System248 / 248
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)248 / 248
Compressor stagingSingle stage248 / 248
Connected capabilityNo248 / 248

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21810823515.208.10194002.18EPA 4574569
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21810823315.208.00193002.19EPA 4574571
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21810823115.208.00192002.19EPA 4574573
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21810822915.208.00193002.18EPA 4574575
5PX*B006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21810822715.208.10193002.19EPA 4574577
5PX*B006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21810822515.208.10193002.19EPA 4574579
5PX*B006AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21810822315.208.10192002.19EPA 4574581
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21810822115.208.10194002.18EPA 4574583
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21810821915.208.00193002.19EPA 4574585
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21810821715.208.10194002.18EPA 4574587
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21810821515.208.00193002.19EPA 4574589
5PX*B004AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810820915.207.80192002.18EPA 4574591
5TXCD010AS3+TSTATAHRI reference: 21811297315.208.10199002.14EPA 4575810
5TXCC009AS3+TSTATAHRI reference: 21811296915.208.10196002.16EPA 4575812
5PX*D010AS3+TSTATAHRI reference: 21811296115.208.10199002.14EPA 4575814
5PX*C009AS3+TSTATAHRI reference: 21811295715.208.10196002.16EPA 4575816
5PX*C005AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21815921615.207.80193002.15EPA 4576628
5TXCD010AS3+TSTAT+ furnace: S9V2D120D5VSBAHRI reference: 21839564515.208.10188002.21EPA 4599408
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21839562915.208.10195002.16EPA 4599418
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21839562715.208.10195002.16EPA 4599420

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.