American Standard / AIR-SOURCE HEAT PUMP

5A6H6042A1

Silver 16 · source records, page 11

248 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,600–41,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 248 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5248 / 248
EER2 · BTU/Wh11.7–12248 / 248
HSPF2 · BTU/Wh7.8–8.5248 / 248
Cooling capacity · BTU/h37,600–41,500248 / 248
Heating capacity at 47°F / 8.3°C · BTU/h37,600–40,500248 / 248
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,200248 / 248
Heating capacity at 5°F / −15°C · BTU/h18,700–19,900248 / 248
COP at 5°F / −15°C2.12–2.32248 / 248
Equipment / loop typeHP - Split System248 / 248
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)248 / 248
Compressor stagingSingle stage248 / 248
Connected capabilityNo248 / 248

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C005AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810831515.207.80193002.15EPA 4574527
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810831315.208.00193002.14EPA 4574529
5PX*C005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21810830915.208.00192002.17EPA 4574531
5PX*C005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21810830515.208.10193002.15EPA 4574533
5PX*C005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21810830315.208.10193002.16EPA 4574535
5PX*C005AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810830115.207.80193002.15EPA 4574537
5PX*C005AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21810829715.208.00193002.16EPA 4574539
5PX*C005AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810829515.207.80193002.15EPA 4574541
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810829315.208.00193002.14EPA 4574543
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810829115.208.00193002.14EPA 4574545
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810828915.208.00193002.14EPA 4574547
5PX*C005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810828715.208.10190002.17EPA 4574549
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810825315.208.00192002.19EPA 4574551
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810825115.208.00193002.18EPA 4574553
5PX*B006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21810824715.208.00194002.16EPA 4574557
5PX*B006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21810824515.208.10192002.20EPA 4574559
5PX*B006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21810824315.208.10192002.20EPA 4574561
5PX*B006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21810824115.208.10192002.18EPA 4574563
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21810823915.208.10194002.18EPA 4574565
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21810823715.208.00193002.19EPA 4574567

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →