American Standard / AIR-SOURCE HEAT PUMP

5A6H6042A1

Silver 16 · source records, page 13

248 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,600–41,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 248 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5248 / 248
EER2 · BTU/Wh11.7–12248 / 248
HSPF2 · BTU/Wh7.8–8.5248 / 248
Cooling capacity · BTU/h37,600–41,500248 / 248
Heating capacity at 47°F / 8.3°C · BTU/h37,600–40,500248 / 248
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,200248 / 248
Heating capacity at 5°F / −15°C · BTU/h18,700–19,900248 / 248
COP at 5°F / −15°C2.12–2.32248 / 248
Equipment / loop typeHP - Split System248 / 248
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)248 / 248
Compressor stagingSingle stage248 / 248
Connected capabilityNo248 / 248

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TEM6D04AV31+TDR+TSTATAHRI reference: 21839561715.208.50194002.19EPA 4599424
5PX*DD10AS3+TSTAT+ furnace: S9X2D120D5PSBAHRI reference: 21839561515.208.10195002.17EPA 4599426
5PX*DD10AS3+TSTAT+ furnace: S9X1D120D5PSBAHRI reference: 21839561315.208.10195002.17EPA 4599428
5PX*CD09AS3+TSTAT+ furnace: *DHMC100CCV4AHRI reference: 21839560715.208.00193002.16EPA 4599432
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21839559715.208.10194002.16EPA 4599440
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21839559515.208.10195002.17EPA 4599442
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21839559315.208.10195002.17EPA 4599444
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21839559115.208.10194002.18EPA 4599446

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →