Silver 15 · source records, page 2
140 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5A6H5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 140 / 140 |
| EER2 · BTU/Wh | 11.7–12 | 140 / 140 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 140 / 140 |
| Cooling capacity · BTU/h | 26,400–29,200 | 140 / 140 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,200–26,400 | 140 / 140 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,300–17,700 | 140 / 140 |
| Heating capacity at 5°F / −15°C · BTU/h | 12,700–13,800 | 140 / 140 |
| COP at 5°F / −15°C | 2–2.2 | 140 / 140 |
| Equipment / loop type | HP - Split System | 140 / 140 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 140 / 140 |
| Compressor staging | Single stage | 140 / 140 |
| Connected capability | No | 140 / 140 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 215567955 | 16.00 | 8.10 | 13600 | 2.10 | EPA 3650146 → |
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 215567965 | 16.00 | 8.00 | 13600 | 2.10 | EPA 3650156 → |
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 215567967 | 16.00 | 8.00 | 13500 | 2.10 | EPA 3650158 → |
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 215567969 | 16.00 | 8.00 | 13600 | 2.10 | EPA 3650160 → |
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 215567971 | 16.00 | 8.00 | 13500 | 2.10 | EPA 3650162 → |
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 215567973 | 16.00 | 8.00 | 13300 | 2.10 | EPA 3650164 → |
5PX*D008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 215568043 | 16.00 | 8.10 | 13400 | 2.10 | EPA 3650205 → |
5TXCD008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 215566271 | 16.00 | 8.10 | 13400 | 2.10 | EPA 3650459 → |
5PX*B006AS3+TSTAT+ furnace: S9X1B040U3PSBAHRI reference: 215567713 | 16.00 | 8.10 | 13800 | 2.10 | EPA 3650995 → |
5TEM6D05AV41+TDR+TSTATAHRI reference: 215610932 | 16.00 | 8.10 | 13800 | 2.10 | EPA 3651476 → |
5TEMCD04AV31+TDR+TSTATAHRI reference: 215863929 | 16.00 | 8.10 | 13300 | 2.20 | EPA 3737600 → |
5TEMCD05AV41+TDR+TSTATAHRI reference: 215863931 | 16.00 | 8.10 | 13300 | 2.20 | EPA 3737603 → |
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 215831425 | 16.00 | 8.10 | 13500 | 2.10 | EPA 3737648 → |
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 215831427 | 16.00 | 8.10 | 13400 | 2.10 | EPA 3737650 → |
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D5VSBAHRI reference: 215831431 | 16.00 | 8.10 | 13500 | 2.10 | EPA 3737652 → |
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 215831447 | 16.00 | 8.10 | 13500 | 2.10 | EPA 3737654 → |
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 215831449 | 16.00 | 8.10 | 13500 | 2.10 | EPA 3737656 → |
5TAMXD05AV41+TSTATAHRI reference: 216056965 | 16.00 | 8.10 | 13300 | 2.10 | EPA 3845944 → |
5TAMXD06AV41+TSTATAHRI reference: 216056967 | 16.00 | 8.00 | 13400 | 2.10 | EPA 3845946 → |
5TEM6D04AV31+TDR+TSTATAHRI reference: 214078350 | 15.20 | 8.10 | 13500 | 2.20 | EPA 3423688 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.