American Standard / AIR-SOURCE HEAT PUMP

5A6H5030A1

Silver 15

140 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity26,400–29,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16140 / 140
EER2 · BTU/Wh11.7–12140 / 140
HSPF2 · BTU/Wh7.8–8.1140 / 140
Cooling capacity · BTU/h26,400–29,200140 / 140
Heating capacity at 47°F / 8.3°C · BTU/h24,200–26,400140 / 140
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,700140 / 140
Heating capacity at 5°F / −15°C · BTU/h12,700–13,800140 / 140
COP at 5°F / −15°C2–2.2140 / 140
Equipment / loop typeHP - Split System140 / 140
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)140 / 140
Compressor stagingSingle stage140 / 140
Connected capabilityNo140 / 140

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21407839216.008.10129002.00EPA 3423794 →
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21407839416.008.10129002.00EPA 3423797 →
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21407840616.008.10129002.00EPA 3423806 →
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21407840416.008.10129002.00EPA 3423807 →
5PX*B006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21556776116.008.10127002.00EPA 3649920 →
5PX*B006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21556771716.008.00137002.10EPA 3649921 →
5PX*B006AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21556771916.008.10138002.10EPA 3649923 →
5PX*B006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21556772316.008.00137002.10EPA 3649925 →
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21556773516.008.10135002.10EPA 3649927 →
5PX*B006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21556774916.008.10127002.00EPA 3649929 →
5PX*B006AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21556775116.008.10127002.00EPA 3649931 →
5PX*B006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21556776316.008.10127002.00EPA 3649933 →
5PX*B006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21556778116.008.00134002.10EPA 3650017 →
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21556786916.008.10137002.10EPA 3650018 →
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D5PSCAHRI reference: 21556800916.008.10136002.10EPA 3650122 →
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D4VSBAHRI reference: 21556801116.008.10136002.10EPA 3650124 →
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21556794716.008.00133002.10EPA 3650138 →
5PX*C007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21556794916.008.00133002.10EPA 3650140 →
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21556795116.008.10135002.10EPA 3650142 →
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556795316.008.10135002.10EPA 3650145 →