Silver 15 · source records, page 3
140 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5A6H5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 140 / 140 |
| EER2 · BTU/Wh | 11.7–12 | 140 / 140 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 140 / 140 |
| Cooling capacity · BTU/h | 26,400–29,200 | 140 / 140 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,200–26,400 | 140 / 140 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,300–17,700 | 140 / 140 |
| Heating capacity at 5°F / −15°C · BTU/h | 12,700–13,800 | 140 / 140 |
| COP at 5°F / −15°C | 2–2.2 | 140 / 140 |
| Equipment / loop type | HP - Split System | 140 / 140 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 140 / 140 |
| Compressor staging | Single stage | 140 / 140 |
| Connected capability | No | 140 / 140 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TEM6D06AV41+TDR+TSTATAHRI reference: 214078352 | 15.20 | 8.10 | 13400 | 2.20 | EPA 3423691 → |
5TEM6D07AV51+TDR+TSTATAHRI reference: 214078354 | 15.20 | 8.10 | 13400 | 2.20 | EPA 3423692 → |
5TXCB004AS3+TSTAT+P0V0A000M30SDAHRI reference: 214078356 | 15.20 | 7.80 | 13200 | 2.00 | EPA 3423694 → |
5TXCB004AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 214078358 | 15.20 | 7.80 | 13300 | 2.00 | EPA 3423696 → |
5TXCB004AS3+TSTAT+ furnace: S9V2B040U3PSBAHRI reference: 214078360 | 15.20 | 8.10 | 13500 | 2.00 | EPA 3423698 → |
5TXCB004AS3+TSTAT+ furnace: S9V2B040U3VSAAHRI reference: 214078362 | 15.20 | 8.10 | 13500 | 2.00 | EPA 3423700 → |
5TXCB004AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 214078364 | 15.20 | 7.80 | 13500 | 2.00 | EPA 3423702 → |
5TXCB004AS3+TSTAT+ furnace: S9V2B080U4PSBAHRI reference: 214078366 | 15.20 | 7.80 | 13200 | 2.00 | EPA 3423704 → |
5TXCB004AS3+TSTAT+ furnace: S9V2B080U4VSAAHRI reference: 214078368 | 15.20 | 7.80 | 13300 | 2.00 | EPA 3423706 → |
5TXCB004AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 214078370 | 15.20 | 7.80 | 13300 | 2.00 | EPA 3423708 → |
5TXCB004AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 214078372 | 15.20 | 7.80 | 13300 | 2.00 | EPA 3423710 → |
5TXCB004AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 214078374 | 15.20 | 7.80 | 13300 | 2.00 | EPA 3423712 → |
5TXCB004AS3+TSTAT+ furnace: *UHMB060ACV3AHRI reference: 214078376 | 15.20 | 7.80 | 13100 | 2.10 | EPA 3423714 → |
5TXCB004AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 214078378 | 15.20 | 7.80 | 13100 | 2.10 | EPA 3423716 → |
5TXCB004AS3+TSTAT+ furnace: *UHMB080ACV3AHRI reference: 214078380 | 15.20 | 7.80 | 13100 | 2.10 | EPA 3423782 → |
5TXCB004AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 214078382 | 15.20 | 7.80 | 13100 | 2.10 | EPA 3423784 → |
5TXCB006AS3+TSTAT+ furnace: L9X1B070U4VSAAHRI reference: 214078384 | 15.20 | 7.80 | 13800 | 2.00 | EPA 3423786 → |
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 214078386 | 15.20 | 7.80 | 13100 | 2.10 | EPA 3423788 → |
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PCAAHRI reference: 214078388 | 15.20 | 7.80 | 12900 | 2.00 | EPA 3423790 → |
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 214078390 | 15.20 | 7.80 | 13300 | 2.10 | EPA 3423792 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.