Amana / AIR-SOURCE HEAT PUMP

AZV7SA4810A*

AZV7SA · source records, page 2

62 published source records · source checked Sep 21, 2026

SEER2 range16.2–17.5BTU/Wh
HSPF2 range8.5–8.8BTU/Wh
Cooling capacity45,500–46,500BTU/h

Each efficiency range summarizes published EPA records for AZV7SA4810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 62 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.2–17.562 / 62
EER2 · BTU/Wh1062 / 62
HSPF2 · BTU/Wh8.5–8.862 / 62
Cooling capacity · BTU/h45,500–46,50062 / 62
Heating capacity at 47°F / 8.3°C · BTU/h46,000–47,50062 / 62
Heating capacity at 17°F / −8.3°C · BTU/h28,400–29,00062 / 62
Heating capacity at 5°F / −15°C · BTU/h33,60062 / 62
COP at 5°F / −15°C262 / 62
Equipment / loop typeHP - Split System62 / 62
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)62 / 62
Compressor stagingContinuously variable62 / 62
Connected capabilityNo62 / 62

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern AZV7SA4810A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight179 lbAZV7S S-SERIES — product specifications · page 3 ↗
Maximum overcurrent protection40 AAZV7S S-SERIES — product specifications · page 3 ↗
Minimum circuit ampacity37.5 AAZV7S S-SERIES — product specifications · page 3 ↗
Shipping weight198 lbAZV7S S-SERIES — product specifications · page 3 ↗
Voltage / phase at 60 Hz208-230/1 V / phaseAZV7S S-SERIES — product specifications · page 3 ↗

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CA*EA6030*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 21543439016.508.80336002.00EPA 3625318 →
CA*EA6030*3A*+ furnace: A*VT961005DNA*Cold climate designationAHRI reference: 21543439716.508.80336002.00EPA 3625325 →
CA*EA6030*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 21543439816.508.80336002.00EPA 3625326 →
CA*EA6030*3A*+ furnace: A*VM971205DNA*Cold climate designationAHRI reference: 21543439916.508.80336002.00EPA 3625327 →
CHPEA4830*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 21543440016.508.50336002.00EPA 3625328 →
CHPEA4830*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 21543440116.508.50336002.00EPA 3625329 →
CHPEA4830*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 21543440216.508.50336002.00EPA 3625330 →
CHPEA4830*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 21543440316.508.50336002.00EPA 3625331 →
CHPEA4830*3A*+ furnace: A*VT961005DNA*Cold climate designationAHRI reference: 21543441016.508.50336002.00EPA 3625338 →
CHPEA4830*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 21543441116.508.50336002.00EPA 3625339 →
CHPEA4830*3A*+ furnace: A*VM971205DNA*Cold climate designationAHRI reference: 21543441216.508.50336002.00EPA 3625340 →
CHPEA6030*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 21543441316.508.50336002.00EPA 3625341 →
CHPEA6030*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 21543441616.508.50336002.00EPA 3625342 →
CHPEA6030*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 21543441416.508.50336002.00EPA 3625343 →
CHPEA6030*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 21543441516.508.50336002.00EPA 3625344 →
CHPEA6030*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 21543442416.508.50336002.00EPA 3625351 →
CHPEA6030*3A*+ furnace: A*VT961005DNA*Cold climate designationAHRI reference: 21543442316.508.50336002.00EPA 3625352 →
CHPEA6030*3A*+ furnace: A*VM971205DNA*Cold climate designationAHRI reference: 21543442516.508.50336002.00EPA 3625353 →
CHPEA6030*3A*+ furnace: A*VC961205DNB*Cold climate designationAHRI reference: 21548777116.508.50336002.00EPA 3627935 →
CA*EA6030*3A*+ furnace: A*VC961205DNB*Cold climate designationAHRI reference: 21548775116.508.80336002.00EPA 3628034 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

AZV7S S-SERIES — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →