AZV7SA4810A*
AZV7SA · source records, page 2
62 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for AZV7SA4810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 62 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.2–17.5 | 62 / 62 |
| EER2 · BTU/Wh | 10 | 62 / 62 |
| HSPF2 · BTU/Wh | 8.5–8.8 | 62 / 62 |
| Cooling capacity · BTU/h | 45,500–46,500 | 62 / 62 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–47,500 | 62 / 62 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,400–29,000 | 62 / 62 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,600 | 62 / 62 |
| COP at 5°F / −15°C | 2 | 62 / 62 |
| Equipment / loop type | HP - Split System | 62 / 62 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 62 / 62 |
| Compressor staging | Continuously variable | 62 / 62 |
| Connected capability | No | 62 / 62 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern AZV7SA4810A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 179 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 40 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 37.5 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Shipping weight | 198 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | AZV7S S-SERIES — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CA*EA6030*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 215434390 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625318 → |
CA*EA6030*3A*+ furnace: A*VT961005DNA*Cold climate designationAHRI reference: 215434397 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625325 → |
CA*EA6030*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 215434398 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625326 → |
CA*EA6030*3A*+ furnace: A*VM971205DNA*Cold climate designationAHRI reference: 215434399 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625327 → |
CHPEA4830*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 215434400 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625328 → |
CHPEA4830*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 215434401 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625329 → |
CHPEA4830*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 215434402 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625330 → |
CHPEA4830*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 215434403 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625331 → |
CHPEA4830*3A*+ furnace: A*VT961005DNA*Cold climate designationAHRI reference: 215434410 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625338 → |
CHPEA4830*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 215434411 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625339 → |
CHPEA4830*3A*+ furnace: A*VM971205DNA*Cold climate designationAHRI reference: 215434412 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625340 → |
CHPEA6030*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 215434413 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625341 → |
CHPEA6030*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 215434416 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625342 → |
CHPEA6030*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 215434414 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625343 → |
CHPEA6030*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 215434415 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625344 → |
CHPEA6030*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 215434424 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625351 → |
CHPEA6030*3A*+ furnace: A*VT961005DNA*Cold climate designationAHRI reference: 215434423 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625352 → |
CHPEA6030*3A*+ furnace: A*VM971205DNA*Cold climate designationAHRI reference: 215434425 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625353 → |
CHPEA6030*3A*+ furnace: A*VC961205DNB*Cold climate designationAHRI reference: 215487771 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3627935 → |
CA*EA6030*3A*+ furnace: A*VC961205DNB*Cold climate designationAHRI reference: 215487751 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3628034 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
AZV7S S-SERIES — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →