Amana / AIR-SOURCE HEAT PUMP

AZV7SA4810A*

AZV7SA

62 published source records · source checked Sep 21, 2026

SEER2 range16.2–17.5BTU/Wh
HSPF2 range8.5–8.8BTU/Wh
Cooling capacity45,500–46,500BTU/h

Each efficiency range summarizes published EPA records for AZV7SA4810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 62 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.2–17.562 / 62
EER2 · BTU/Wh1062 / 62
HSPF2 · BTU/Wh8.5–8.862 / 62
Cooling capacity · BTU/h45,500–46,50062 / 62
Heating capacity at 47°F / 8.3°C · BTU/h46,000–47,50062 / 62
Heating capacity at 17°F / −8.3°C · BTU/h28,400–29,00062 / 62
Heating capacity at 5°F / −15°C · BTU/h33,60062 / 62
COP at 5°F / −15°C262 / 62
Equipment / loop typeHP - Split System62 / 62
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)62 / 62
Compressor stagingContinuously variable62 / 62
Connected capabilityNo62 / 62

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern AZV7SA4810A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight179 lbAZV7S S-SERIES — product specifications · page 3
Maximum overcurrent protection40 AAZV7S S-SERIES — product specifications · page 3
Minimum circuit ampacity37.5 AAZV7S S-SERIES — product specifications · page 3
Shipping weight198 lbAZV7S S-SERIES — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseAZV7S S-SERIES — product specifications · page 3

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
AHVE60DP1300A*Cold climate designationAHRI reference: 21542918917.508.80336002.00EPA 3625025
AHVE60DP0300A*Cold climate designationAHRI reference: 21542975017.508.80336002.00EPA 3625070
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21543395417.508.80336002.00EPA 3625244
CHPEA4830*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21543395617.508.50336002.00EPA 3625246
CHPEA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21543395817.508.50336002.00EPA 3625248
CA*EA6030*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758933317.508.80336002.00EPA 4497769
CHPEA4830*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758933517.508.50336002.00EPA 4497771
CHPEA6030*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758933717.508.50336002.00EPA 4497773
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21543395317.008.80336002.00EPA 3625243
CHPEA4830*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21543395517.008.50336002.00EPA 3625245
CHPEA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21543395717.008.50336002.00EPA 3625247
CA*EA6030*3A*+ furnace: A*VT800805D*A*Cold climate designationAHRI reference: 21543439617.008.80336002.00EPA 3625324
CHPEA4830*3A*+ furnace: A*VT800805D*A*Cold climate designationAHRI reference: 21543440917.008.50336002.00EPA 3625337
CHPEA6030*3A*+ furnace: A*VT800805D*A*Cold climate designationAHRI reference: 21543442217.008.50336002.00EPA 3625350
CA*EA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758933217.008.80336002.00EPA 4497768
CHPEA4830*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758933417.008.50336002.00EPA 4497770
CHPEA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758933617.008.50336002.00EPA 4497772
CA*EA6030*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 21543438716.508.80336002.00EPA 3625315
CA*EA6030*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 21543438916.508.80336002.00EPA 3625316
CA*EA6030*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 21543438816.508.80336002.00EPA 3625317

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

AZV7S S-SERIES — product specificationsManufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →